Port-monitor – HP Integrity BL870c i2 Server-Blade User Manual
Page 44
Command line 44
Item
Description
->set network Network1 PrefSpeedType=Custom PrefSpeed=4000
MaxSpeedType=Custom MaxSpeed=6000
Modifies network to preferred connection speed of 4Gb and maximum connection
speed of 6Gb
Item
Description
show network
Display all Ethernet networks in the domain.
Syntax
show network [
Parameter
NetworkName
(optional)
Name of an existing network in the VC domain. "*" displays a detailed view of all
the networks. If not specified, a summary view of the networks is displayed.
Examples
->show network
Displays a summary listing of all networks
->show network *
Displays detailed information for all networks
->show network MyNetwork
Displays detailed information for a specific network
port-monitor
Manage port monitor configuration.
Supported actions: help, add, remove, set, show
Item
Description
add port monitor
Add a new network analyzer port and other ports to be monitored.
Syntax
add port-monitor [AnalyzerPort=
[Speed=
[Duplex=
[Direction=
Properties
AnalyzerPort
(optional)
The uplink port that is used for monitoring network traffic. Only one port can be
configured as the analyzer port.
After a port has been allocated to port monitoring, it is not available for use in
VC networks and shared uplink sets.
The format of the network analyzer port is
If the enclosure ID is not specified, the default enclosure is the local enclosure
where the domain resides.
Speed (optional)
The port speed for the network analyzer port. Valid values include "Auto",
"10Mb", "100Mb", "1Gb", "10Gb", and "Disabled". The default value is
"Auto".
If there is no connector present on the analyzer port, only "Auto" and
"Disabled" can be configured as a possible speed. Speed restrictions apply.