Command line 24

Item

Description

Setting the value to "true" restricts the server network connections to be

selected from a single shared uplink, and the VLAN ID cannot be modified.
Setting the value to "false" enables the user to select any VC Ethernet network

for the server Ethernet connections, and VLAN ID mappings can be modified
to ensure uniqueness.
SharedServerVLanId can be "true" only if VLanTagControl is set to "Map".

PrefSpeedType

(optional)

The default connection speed for any Ethernet connection using multiple

networks. Valid values include "Auto" and "Custom". "Custom" allows the
user to configure the preferred speed. The default value is "Auto".

PrefSpeed (required

if PrefSpeedType is

Custom)

The default connection speed for any Ethernet connection using multiple
networks. Valid values range from 100Mb to 10Gb in 100Mb increments.

MaxSpeedType

(optional)

Maximum connection speed for any Ethernet connection using multiple

networks. Valid values include "UnRestricted" and "Custom". "Custom"
allows the user to configure the preferred speed. The default value is
"Unrestricted".

MaxSpeed (required

if MaxpeedType is

Custom)

The maximum connection speed for any Ethernet connection using multiple
networks. Valid values range from: 100Mb to 10Gb in 100Mb increments.

Examples

->set enet-vlan VLanTagControl=Map

SharedServerVLanId=true
Sets the VLanTagControl to Map and SharedServerVLanId to Enabled

->set enet-vlan PrefSpeedType=Custom PrefSpeed=500

MaxSpeedType=Custom MaxSpeed=2500
Sets the preferred connection speed for all connections using multiple
networks to 500Mb, and the maximum connection speed to 2.5Gb

Item

Description

show enet-vlan

Display general Ethernet VLAN configuration settings.

Syntax

show enet-vlan

Example

->show enet-vlan
Displays Ethernet VLAN configuration settings

external-manager

Manage external manager settings and information.
Supported actions: remove, help, set, show

Item

Description

remove external-

manager

Remove an existing external manager (VCEM) and regain local management

profile control of the domain.
When releasing the profile control, it is mandatory to specify values for each
MacType, WwnType, and ServerIdType.

Syntax

remove external-manager [-quiet] [UserName=]

[MacType=] [MacStart=