Ldap – HP Integrity BL870c i2 Server-Blade User Manual
Page 33
Command line 33
Item
Description
Syntax
remove interconnect
Parameter
ModuleID(required)
The ID of the module to remove. The ID format is
to modules in the domain, use the show interconnect command.
Examples
->remove interconnect enc0:2
Removes a specific interconnect module (bay 2) from the domain
->remove interconnect *
Removes all interconnect modules from the domain that are not present
physically in any enclosure
->remove interconnect enc0:*
Removes all interconnect modules that are not present physically in a specific
enclosure
->remove interconnect *:2
Removes interconnect modules (bay 2) from the domain that are not
physically present in all enclosures
Item
Description
show interconnect
Display all interconnect modules known to exist in the domain.
Syntax
show interconnect [
Property
ModuleID (optional)
The ID of the interconnect module. “*” displays detailed view of all the
modules in the VC domain. If not specified, a summary output of all the
modules appears.
Examples
->show interconnect
Displays a summary listing of all interconnect modules
->show interconnect *
Displays detailed information for all interconnect modules
->show interconnect *:5
Displays detailed information for all enclosures with interconnect modules in
interconnect bay number 5
->show interconnect enc0:*
Displays interconnect modules in all bays of a specific enclosure
->show interconnect enc0:3
Displays detailed information on a specific interconnect module in
interconnect bay 3 of the primary enclosure
ldap
Manage Virtual Connect directory server authentication settings.
Supported actions: help, set, show