Systems insight display led combinations, Systems insight display led combin, Ations – HP StorageWorks X3000 Network Storage Systems User Manual
Page 39: Systems, Insight display led combinations
Systems Insight Display LED combinations
When the internal health LED on the front panel illuminates either amber or red, the server is
experiencing a health event. Combinations of illuminated system LEDs and the internal health LED
indicate system status.
Table 11 Systems Insight Display LEDs and internal health LED combinations
Status
Internal health LED
color
Systems Insight
Display LED and
color
One or more of the following conditions may exist:
•
Processor in socket X has failed.
•
Processor X is not installed in the socket.
•
Processor X is unsupported.
•
ROM detects a failed processor during POST.
Red
Processor failure,
socket X (amber)
Processor in socket X is in a pre-failure condition.
Amber
One or more of the following conditions may exist:
•
PPM in slot X has failed.
•
PPM is not installed in slot X, but the corresponding pro-
cessor is installed.
Red
PPM failure, slot X
(amber)
DIMM in slot X has failed.
Red
DIMM failure, slot X
(amber)
DIMM in slot X is in a pre-failure condition.
Amber
One or more DIMMs has failed. Test each bank of DIMMs by
removing all other DIMMs. Isolate the failed DIMM by replacing
each DIMM in a bank with a known working DIMM.
Red
DIMM failure, all
slots in one bank
(amber)
One or more DIMMs has failed. Test each bank of DIMMs by
removing all other DIMMs. Isolate the failed DIMM by replacing
each DIMM in a bank with a known working DIMM.
Red
DIMM failure, all
slots in all banks
(amber)
Bank X failed over to the online spare memory bank.
Amber
Online spare
memory (amber)
Invalid online spare memory configuration.
Red
Online spare
memory (flashing
amber)
Online spare memory enabled and not failed.
Green
Online spare
memory (green)
Bank(s) X failed over to the mirrored memory bank(s).
Amber
Mirrored memory
(amber)
Invalid mirrored memory configuration.
Red
Mirrored memory
(flashing (amber)
Mirrored memory enabled and not failed.
Green
Mirrored memory
(green)
X1000 and X3000 Network Storage System
39