Configuring the Tape Drive for the NonStop S-Series
Server
N1524A ACL Installation and User’s Guide for the NonStop S-Series Tape Enclosure — 527340-001
3 -2
PMF CRU
PMF CRU
To add the tape drive to the server configuration database, use the SCF ADD TAPE
command to add the tape drive.
Before issuing these commands, check that the
tape drive is installed properly.
To add the tape drive:
-> SCF
-> ADD TAPE $ACLTAP, SENDTO STORAGE, LOCATION (1,1,50),
DEVICEID 5, PRIMARYCPU 0, BACKUPCPU 1
-> START TAPE $ACLTAP
-> STATUS TAPE $ACLTAP, DETAIL
In this example:
•
The LOCATION attribute specifies the location (group, module, and slot) of
the PMF CRU (adapter) to which the tape drive is attached.
•
The DEVICEID attribute shows the device ID that is configured for the
device. This ID must match the SCSI ID that is physically set in the device.
•
The PRIMARYCPU attribute specifies the processor in which the primary
tape process should execute.
•
The BACKUPCPU attribute specifies the processor in which the tape
process starts its backup process.
For more information on the ADD and STATUS commands, see the SCF