CLASS TAPECATALOG DEFINE
Consistency Checks

To display the current CLASS TAPECATALOG DEFINE attribute values, use the
SHOW DEFINE command at the TACL prompt. SHOW DEFINE also checks the
attributes for consistency and returns the number of the first consistency check that
fails. For details on the SHOW DEFINE command, see the TACL Reference Manual.

Table C-1. TAPECATALOG DEFINE Consistency Checks

Check

Number

Description

1

Use RETENTION or EXPIRATION, but not both.

5

If you specify RECFORM F, BLOCKLEN must be a multiple of RECLEN.

6

Use DEVICE or AVRSYSTEM, but not both.

10

RECLEN cannot be specified as 0 when BLOCKLEN is unspecified.

101

USE cannot be used with LABELS OMITTED.

102

USE is required.

103

FILEID is required.

104

CATALOG OFF is required when LABELS BYPASS or LABELS OMITTED is used.

105

COMMENT, OWNER, RETENTION, TAPEMODE, VERSION NEW, and VOLUME
SCRATCH cannot be used with USE IN.

106

VOLUME is required with USE EXTEND.

107

DEVICE is required when LABELS BYPASS or LABELS OMITTED is used.

108

VOLUME is required when LABELS ANSI, LABELS BACKUP, LABELS IBM, or
LABELS IBMBACKUP is used with USE IN and CATALOG OFF.

109

The character string for OWNER exceeds the maximum length for LABELS IBM or
IBM BACKUP.

110

BLOCKLEN, RECFORM, and RECLEN cannot be used with LABELS BACKUP,
LABELS BYPASS, or LABELS OMITTED.

112

EBCDIC can be used only with LABELS IBM or LABELS IBMBACKUP.

113

AVRSYSTEM, COMMENT, FILECAT, FILEID, GEN, OWNER, POOL,
RETENTION, USE, VERSION, and VOLCAT cannot be used with LABELS
BYPASS.

114

AVRSYSTEM, OWNER, and VOLUME cannot be used with LABELS OMITTED.

115

USE EXTEND cannot be used with LABELS BACKUP or LABELS IBMBACKUP

116

GEN must be an absolute value when CATALOG OFF is used.

117

GEN cannot be specified as a relative generation when USE OUT is used.

118

GEN cannot be +1 when USE IN is used.