Specifications, Environmental specifications, Mechanical specifications – HP ProLiant ML110 G7 Server User Manual
Page 97: Power supply specifications
![background image](/manuals/395716/97/background.png)
Specifications 97
Specifications
Environmental specifications
Specification
Value
Temperature range*
Operating
10°C to 35°C (50°F to 95°F)
Shipping
-30°C to 50°C (-22°F to 122°F)
Storage
-30°C to 60°C (-22°F to 140°F)
Maximum wet bulb
temperature
28°C (82.4°F)
Relative humidity
(noncondensing)**
Operating
10% to 90%
Non-operating
5% to 95%
* All temperature ratings shown are for sea level. An altitude derating of 1°C per 300 m (1.8°F per 1,000 ft) to 3048
m (10,000 ft) is applicable. No direct sunlight allowed.
** Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F). Altitude maximum for
storage corresponds to a pressure minimum of 70 KPa.
Mechanical specifications
Specification
Value
Dimensions
Height
36.74 cm (14.46 in)
Depth
47.3 cm (18.60 in)
Width
17.48 cm (6.882 in)
Weight (maximum)
14.68 kg (32.30 lb)
Power supply specifications
Depending on installed options, the server is configured with one of the following power supplies:
•
HP ProLiant 460W Power Supply
NOTE:
If two 460 W power supplies are installed, one serves as the redundant power supply.
Specification
Value
Input requirements
Rated input voltage
100 to 120 VAC, 200 to
240 VAC