Register send-alarm-to-server event, Interface uri, Access method – HP Intelligent Management Center Licenses User Manual
Page 311: Returned result, Interface uri access method returned result
Register Send-Alarm-to-Server Event
Register the send-alarm-to-server event and filter alarms to be sent with certain criteria.
Interface URI
/events
Access Method
HTTP
GET
Parameters
Query parameters
Event type.
type
Integer type. The value is 11, indicating the send-alarm-to-server event.
UUID.
uuid
String type. Uniquely identifies a client.
Alarm level.
alarmLevel
Integer type, supporting multiple elements. Optional. No default value. If this parameter is not set,
then all levels of alarms will be forwarded. For the valid values, see Query Alarm Levels.
Custom view ID.
customView
Long integer type. Optional. No default value.
Device IP address.
deviceIp
String type, supporting multiple elements. Optional. No default value.
IP segment.
ipSegment
String type, supporting multiple elements. Optional. No default value. The IP range is expressed with
a hyphen (-). For example, 192.168.0.1-192.168.0.254.
Alarm event OID.
eventOid
String type, supporting multiple elements. Optional. No default value.
Returned Result
Status codes
•
202 (Accepted): Successfully registered.
Message header
HTTP/1.1 202 Accepted
Content-Type: application/xml
Register Send-Alarm-to-Server Event
311