Modify polling interval, Interface uri, Access method – HP Intelligent Management Center Licenses User Manual
Page 104: Returned result, Interface uri access method returned result

Modify Polling Interval
Modify polling interval for a device based on device ID.
Interface URI
/plat/res/device/{id}/updatePollInterval
Access Method
HTTP
PUT
Parameters
Path parameter
Device ID.
id
Long integer type. Required. No default value.
Message body
Element description
device sub-elements
Set polling interval.
configPollTime
Integer type, in minutes. Optional. If the element does not exist, the value is not changed. If the
element exists, the value cannot be null
Status polling interval.
statePollTime
Integer type, in seconds. Optional. If the element does not exist, the value is not changed. If the
element exists, the value cannot be null.
Returned Result
Status codes
•
204 (No Content): Success.
•
404 (Not Found): No data is found with the ID.
•
409 (Conflict): Failure. See “
.”
Message header
HTTP/1.1 204 No Content
...
104 Network Resource Management