Modify unknown access policy, Interface uri, Access method – HP Intelligent Management Center Licenses User Manual
Page 277: Interface uri access method
Modify Unknown Access Policy
Modify the unknown access policy.
Interface URI
/res/access/strategy/unknown
Access Method
HTTP
PUT
Parameters
None
Message body
Elements
accessStrategy sub-elements
Whether or not to send alarms. 0 for no. 1 for yes.
sendFaultType
Integer type. Optional. If the element does not exist, the value is not changed. If the element exists,
the value cannot be null.
Interface shutdown type. 0 for no shutdown. 1 for immediate shutdown. 2 for delayed shutdown.
closeIfType
Integer type. Optional. If the element does not exist, the value is not changed. If the element exists,
the value cannot be null.
Whether or not to bring up the interface after it is shut down. 0 for no. 1 for yes.
openIfType
Integer type. Optional. If the element does not exist, the value is not changed. If the element exists,
the value cannot be null.
Time delay before shutting down the interface, in seconds.
closeIfDelay
Integer type. Optional. If the element does not exist, the value is not changed. If the element exists,
the value cannot be null.
Time delay before bringing up the interface, in seconds.
openIfDelay
Integer type. Optional. If the element does not exist, the value is not changed. If the element exists,
the value cannot be null.
Whether or not the policy is valid when an unknown access is detected.0 for yes. 1 for no.
accessType
Integer type. Optional. If the element does not exist, the value is not changed. If the element exists,
the value cannot be null.
Modify Unknown Access Policy 277