beautypg.com

HP Smart Update Manager (User Guide) User Manual

Page 53

background image

Possible values

Description

Parameter

YES

, NO

Enables the credentials of the local
host to be used as the credentials to

USECURRENTCREDENTIAL

access the targets instead of providing
the user name and password explicitly
for each target.

The assumption is that the current
credentials are valid for the targets
that are being accessed. (Applies to
Windows only.)

YES

, NO

Instructs HP SUM to include the
components from the HP FTP site

WEBUPDATENEEDED

(

ftp://ftp.hp.com

) in the list of possible

updates.

String value

Use a proxy server (and port number)
to access the HP FTP site (

ftp://

ftp.hp.com

).

USEPROXYSERVER

For example, 11.22.33.44:80

Web URL (for example,
autoproxy.com

)

Include a proxy script to access the
HP FTP site (

ftp://ftp.hp.com

).

USEPROXYSCRIPT

YES

, NO (default)

Instructs HP SUM to delete the input
file after it has been read.

DELETEINPUTFILE

OmitHost

(default),

OmitComponent

, Force

This parameter instructs HP SUM how
to proceed when a component has a
failed dependency.

ONFAILEDDEPENDENCY

The default of OmitHost causes the
host to be put in a failure state, and
no installation is attempted on it.

OmitComponent

clears the affected

components and proceeds with any
updates that do not have dependency
failures. Force attempts all updates,
even if they have dependency failures.

IP address, DNS name

This parameter is the IP address or the
DNS name of a remote server, remote

HOST

iLO NIC port, Virtual Connect Ethernet
or Fibre Channel Module for c-Class
BladeSystem, or BladeSystem OA.

When two OAs are in an enclosure,
this parameter is the active OA. When
specifying the IP address, you can use
either the IPv4 or IPv6 format.

This parameter specifies an already
defined group name in the HP SUM
GUI.

Logs in to the target hosts with your
user ID.

UID

Uses the password for the user ID
specified in the UID.

PWD

The password is used to log in to
target hosts.

Log file name

Redirects the output from HP SUM or
the HP BladeSystem c-Class OA flash

LOGFILENAME = "path"

utility to a different directory than the
default location.

Input files

53