Input file parameters – HP Smart Update Manager (User Guide) User Manual
Page 50
Input file parameters
Possible values
Description
Parameter
YES
, NO
This parameter causes the installation
to run silently without GUI or console
SILENT
output. All data is written to the log
file. Any generated prompts use the
default option and continue the
installation without user input.
If a component requires input before
installation (such as configuration
information), the component
installation fails (unless the
IGNOREERRORS
=
"FailedDependencies" parameter is
supplied), and an error message is
written to the log file.
/targettype vc
This parameter specifies the target
type and can shorten the discovery
process.
TARGETTYPE
The following are valid target
types:
•
Server
•
Windows
•
Linux
•
HPUX
•
EVA
or Command View for
EVA
•
FC Switch
or Fibre
Channel Switch
•
OA
or Onboard
Administrator
•
SUPERDOME 2
or
SUPERDOME2
or Superdome
2 Onboard Administrator
•
iLO
•
VC
or Virtual Connect
•
HP SAS
or HP SAS B/L
Interconnect Switch
•
VMware
or VMware Host
•
iPDU
or Intelligent
Power Distribution Unit
(iPDU)
If you use the command with a
group, the HP SUM assumes all
targets in the group are the same
target type.
YES
, NO
Forces updates to both firmware and
software components.
FORCEALL
YES
, NO
Forces updates to firmware
components.
FORCEROM
YES
, NO
Forces updates to software
components.
FORCESOFTWARE
YES
, NO
Enables you to override or downgrade
an existing installation of components
in the selected bundle.
FORCEBUNDLE
50
Using scripts to deploy updates