5.

When you are finished, click OK.

To edit an existing group:
1.

Select targets in the Available Targets list and then click Add to add one or more targets to
the group.

2.

Select the targets in the Targets in Group list, and then click Remove to remove one or more
targets from the group.

3.

Enter a Description (optional).

4.

Click OK.

Pending firmware updates for iLO (HP Integrity servers only)

If you update a previously updated Integrity server via iLO but did not power down and reboot to
activate the system firmware change, HP SUM asks you what to do with the pending update. You
can choose to:

Leave the system for manual reboot to activate.

This disables the target in HP SUM and you will need to manually power down and reboot
the system to activate the pending update. After the reboot, you can open HP SUM and
proceed with the firmware update.

Let HP SUM power down the system and reboot the operating system to let the activation
happen.

HP SUM sends a graceful shutdown request to the operating system and then powers down
the server to let the activation occur. Then HP SUM powers back up the server. After the system
restarts, you can continue with new updates.

Let HP SUM cancel the pending update.

This option will cancel the staged update. After the HP SUM finishes the cancellation, HP SUM
will rediscover the target and you can continue with the new updates.

Before you cancel a pending update, make sure it is not a critical fix that prevents you from applying
current updates.

If you are updating an HP Integrity BL8x0c i2/i4 or rx2800 i2/i4 server, the firmware activation
will occur during the next power down. To manually check the firmware activation while the system
is powered down, run the iLO3 Management Processor Command Menu command, fw.

NOTE:

Cancelling an update and not performing new updates might leave the server in a state

where you cannot boot it. The iLO and system firmware might be mixed and incompatible. If you
cancel a pending update, make sure you perform a new full firmware update.