background image

2.

Select IP Address Range, Port Address, or LDAP Scan for Remote Targets, and then click OK.

IP Address–Enables you to search a range of IP addresses in IPv4 or IPv6 format. Enter
the required address range information, click Search, select the target, and then click
Add to List.

NOTE:

HP SUM searches only c-class blocks of IP addresses, and a maximum of 255

targets. For example, you can search for IP address 192.168.1.1 through 192.168.1.255,
but HP SUM does not support searching IP addresses 192.168.1.1 through
192.168.3.255.

Port Address–Enables you to search in a range of IP addresses and specific port address.

LDAP Scan for Remote Targets–Enables you to search for targets using an LDAP query.

NOTE:

HP SUM will prompt whether or not to continue at the end of the discovery process if a

Linux server belongs to a Serviceguard cluster and the target is active. Click Yes or No. If you
continue and perform the update, you must reboot the target to activate the update.

Adding a single target

1.

Click Add Single Target.

2.

Type the IP or DNS address of the target.

3.

Select the type of target from the dropdown list (optional). If you leave this field as the default
setting, HP SUM detects the type of target during the discovery process. If you select the correct
target type, the discovery process is faster.

4.

Type a brief description of the target (optional).

5.

Enter the username and password.

If you are using a Linux system and want to use a non-root user, click Use different user for
execution of components. Enter the user and password.

NOTE:

The user must be part of the root group.

6.

Select the checkbox if you want to validate the credentials and start the target discovery
process when you create the target.

7.

If HP SUM finds an update already running on the target, select whether to continue the update
or cancel the update and use update planned in the current HP SUM session.

8.

Click OK. This begins the discovery process of the target that is added.

Updating VMware firmware

The following must be true to update a VMware ESXi 5.0 target:

The target must be running VMware ESXi 5.0 or later.

The target must be active on the network so HP SUM can detect it.

You are not attempting to run HP SUM on the VMware ESXi 5.0 or later target. You cannot
execute HP SUM locally to update a VMware ESXi 5.0 target.

You are executing HP SUM on a Windows or Linux host computer.

The VMware server must be running hp-smx-provider-500.03.01.2–434156 or later. You can
get the bundle from one of the following locations:

Version 1.3.5 or later of the HP Insight Management WBEM Provider offline bundle. You
can download the bundle from the HP Online Depot at

http://vibsdepot.hp.com

.

The provider is included in version 5.25 of the HP Custom Image. You can download
the HP Custom Image ISO from the Custom VMware ESXi Image for HP ProLiant Servers
website at

http://www.hp.com/go/esxidownload

.