Alliance Laundry Systems PHM802N User Manual
Page 40
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Specifications and Dimensions
F8138601
38
Figure 24
Connecting External Liquid Supplies to the
Washer-Extractor
1. Remove knockout from supply dispenser. Refer
to Figure 24. Plugs are assembled inside the
tubing ring.
2. Install PG connector in hole with strain reliefs,
included in the seal nut.
3. Insert tubes through PG base. Do not remove
cups. Tube should extend into the plastic cup,
with the exception of the softener tube, which
should be routed to the outside of the cup.
4. Tighten the seal nut to prevent tubing from
escaping the assembly.
5. Before operating machine, confirm lid is
completely closed.
Do not attempt to make chemical injection electrical
connections to points other than those provided
specifically for that purpose by the factory.
A bracket, which is located on the left side of the
control module, has been provided for mounting the
external supply controls. This bracket is present only
on models made through 6/30/08. Refer to Figures 3
and 4.
PHM559N
1
Tubing from Pump
2
Seal Nut
3
Tubing Ring
4
Base
5
Lid
6
Nut
PHM559N
3
1
2
4
5
6
Chemical Injection Supply System
Number of dry supply compartments
5
Number of external liquid supply
connections
8
Liquid supply connection size, in. (mm)
0.625 (15.9)