Specifications and Dimensions
35
F8138601
Voltage Designation
Non-Electric Heat
Machines (Standard)
Electric Heat Machines
Mo
del
Co
de
Vo
lta
g
e
Cy
cl
e
Phase
Wi
re
Full Lo
ad
Amp
s
Br
eak
er
*A
WG
*mm
2
Full Load
Amp
s
Br
eak
er
*A
WG
*mm
2
35
X
200 – 240 50/60
1/3
2/3
12/8
15/15 14/14 2.5/2.5
NOT AVAILABLE
Q
200 – 240 50/60
3
3
8
15
14
2.5
42
50
6
16
R
380 – 480 50/60
3
3
6
15
14
2.5
23
30
10
6
60
X
200 – 240 50/60
1/3
2/3
15/9
20/15 12/14
4/2.5
NOT AVAILABLE
Q
200 – 240 50/60
3
3
9
15
14
2.5
71
80
3
25
R
380 – 480 50/60
3
3
7
15
14
2.5
37
40
8
10
80
Q
200 – 240 50/60
3
3
9
15
14
2.5
105
110
1
50
R
380 – 480 50/60
3
3
10
15
14
2.5
39
40
8
10
100
Q
200 – 240 50/60
3
3
10
15
14
2.5
108
110
1
50
R
380 – 480 50/60
3
3
10
15
14
2.5
40
50
6
16
125
Q
200 – 240 50/60
3
3
9
15
14
2.5
NOT AVAILABLE
R
380 – 480 50/60
3
3
8
15
14
2.5
150
Q
200 – 240 50/60
3
3
16
20
12
4
NOT AVAILABLE
R
380 – 480 50/60
3
3
11
15
14
2.5
* NOTE: Wire sizing listed in this table is based on Article 310, Table 310.16 of the NEC; at 104°F (40°C) ambient
temperature. Follow your local electrical codes. Use only copper conductors, rated for 194ºF (90°C) or higher, type
THHN or better. No more than three current carrying conductors per raceway. Contact your local Authority having
jurisdiction if you have questions. Circuit breakers should be UL 489 listed or better. Single phase circuit breakers
for single phase machines only; three phase circuit breakers for all others.
Table 7