Machine Mounting and Grouting
After the concrete has cured, proceed as follows:
1. Place the washer-extractor adjacent to the
foundation. Do not attempt to move the machine
by pushing on the sides. Always insert a pry bar
or other device under the bottom frame of the
machine to move it.
2. Remove the wood skid by unscrewing the
carriage bolts holding the skid to the bottom
frame of the washer-extractor.
3. Place the washer-extractor carefully over the
anchor bolts. Never attempt to lift the machine by
the door handle or by pushing on the cover
panels.
4. Raise and level the washer-extractor 0.5 inch
(1.27 cm) off the floor on three points, using
spacers such as nut fasteners.
5. Fill the space between the washer-extractor base
and the floor with a good quality non-shrinking
machinery precision grout to ensure a stable
installation. Grout completely under all frame
members. (Remove front panel and back panel to
gain access to all frame members.) Refer to
Figure 13. Force grout under machine base until
all voids are filled.
6. Remove the spacers carefully, allowing the
machine to settle into the wet grout.
7. Before grout sets completely, make a drain
opening in the rear of the washer-extractor
grouting with a stiff piece of wire; this opening
should be approximately 1/2 inch (1.27 cm) wide
to allow any surface water build-up under the
base of the machine to drain away. Do not omit
this step.
8. Position the mounting bolt lockwashers and
locknuts on the anchor bolts and finger-tighten
locknuts to machine base.
9. After the grout is completely dry, tighten the
locknuts by even increments – one after the other –
until all are tightened evenly and the washer-
extractor is fastened securely to the floor.
10. After installing bolts using a rebar frame, torque
5/8 inch bolts (35 model) to 90 ft. lb. and torque
3/4 inch bolts (60-150 models) to 160 ft. lb.
When using bolts not specified by Alliance
Laundry Systems, refer to the specifications
provided with the bolt.
NOTE: Check and retighten the locknuts after five
to ten days of operation and every month
thereafter.