Chemical injection supply system, Warning – Alliance Laundry Systems PHM802N User Manual
Page 39
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Specifications and Dimensions
37
F8138601
Chemical Injection Supply System
Undiluted chemical dripping can damage the washer-
extractor. Therefore, all chemical supply dispenser
pumps should be mounted below the washer’s
injection point. All dispenser tubing should also run
below the injection point. Loops do not prevent drips
if these instructions are not followed. Failure to follow
these instructions could damage the machine and void
the warranty. Figure 23 shows a typical Chemical
Injection Supply System.
Wear eye and hand protection when
handling chemicals; always avoid direct
contact with raw chemicals. Read the
manufacturer’s directions for accidental
contact before handling chemicals.
Ensure an eye-rinse facility and an
emergency shower are within easy reach.
Check at regular intervals for chemical
leaks.
SW016
WARNING
PHM825N
1
Injection Point
3
Chemical Dispenser Pump Outlet
2
Loops
4
PVC Pipe
Figure 23
1
3
4
2