ESC iXC1
Retrieve number of copies
[ASCII]
ESC i X C 1 n1 n2
[Decimal]
27 105 88 67 49 nd1 nd2
[Hexadecimal]
1B 69 58 43 31 nh1 nh2
[Parameters]
nh1:00h (Fixed)
nh2:00h
(Fixed)
[Description]
・
Retrieves the number of copies specified to be printed.
・
4-byte data is returned from the machine.
[1]: 02h (Fixed)
[2]: 00h (Fixed)
[3, 4]:
nh3 nh4 Settings
nh3+(nh4*256)
: Print start received character count
・
The retrieved value is a value specified by a static command.
[Example]
・
When the number of copies is set to 500:
If the command ESC i X C 1 00h 00h (1Bh 69h 58h 43h 31h 00h 00h) is sent to the
machine, 02h 00h F4h 01h is returned from the machine. 244 (F4h) + (1 (01h) * 256) =
500