ESC iXm1

Retrieve character code set

[ASCII]

ESC i X m 1 n1 n2

[Decimal]

27 105 88 109 49 nd1 nd2

[Hexadecimal]

1B 69 58 6D 31 nh1 nh2

[Parameters]

nh1:00h (Fixed)

nh2:00h (Fixed)

[Description]

Retrieves the specified character code set. (For details on the character code sets, refer

to the character code tables.)

3-byte data is returned from the machine.
[1]:01h (Fixed)

[2]:00h (Fixed)

[3]:

Setting

00h: Brother standard

01h: Windows1250 (Eastern Europe)

02h: Windows1252 (Western Europe)

The retrieved value is a value specified by a static command.

[Example]

When the character code set is set to the Brother standard:
If ESC i X m 1 00h 00h (1Bh 69h 58h 6Dh 31h 00h 00h) is sent to the machine, the

following is returned from the machine.

01h 00h 00h