Notice number, 4-2) error information, 4-3) error description – Brother MW-260 User Manual
Page 17: 4-2) error information: 1-4-3) error description

17
Notice number
Name
Value
Invalid 00
Hex
Not used
01 Hex
Not used
02 Hex
Not used
03 Hex
Not used
04 Hex
Not used
05 Hex
1-4-2) Error information:
Error Information 1 table:
Data Flag
Mask
Description
Bit 0
0x01
Paper cassette empty error (or Paper cassette
wrong distance error. It is not paper empty)
Bit 1
0x02
N/A
Bit 2
0x04
Paper Jam
Bit 3
0x08
Battery empty
Bit 4
0x10
N/A
Bit 5
0x20
N/A
Bit 6
0x40
Adapter overvoltage limit
Bit 7
0x80
N/A
Error Information 2 table:
Data Flag
Mask
Description
Bit 0
0x01
Paper cassette was changed during printing
Bit 1
0x02
N/A
Bit 2
0x04
Program error (communication error or buffer full
error. ESC/P command data exceeded 64 KB
limit.)
MW-145BT and MW-260 are available the error.
MW-120 and MW-140BT are not available.
Bit 3
0x08
N/A (communication error)
MW-120 and MW-140BT are available the error.
MW-145BT and MW-260 are not available (N/A).
Bit 4
0x10
N/A
Bit 5
0x20
Print head above high temperature limit
Bit 6
0x40
Feed error or paper empty
Bit 7
0x80
System error (EEPROM error and other fatal
errors)
1-4-3) Error description
a. “Paper cassette empty error” / “Paper cassette wrong distance error”
An error status (setting bit 0 in the error information 1 table) is sent to the host device when a printer is
detects an empty paper cassette or paper cassette wrong distance after a page feed command is received.