5 Parameters

BU 0540 GB-1013

41

Parameter
No. [Array]

Name

Factory

setting

Super-

visor

Setting after commissioning

P 1

P 2

P 3

P 4

P407

Adjustment 2: 0% [V]

0.0

S

P408

Adjustment 2: 100% [V]

10.0

S

P409

Analog input filter 2 [ms]

100

S

P410

(P)

Min. freq. auxiliary setpoint [Hz]

0.0

P411

(P)

Max. freq. auxiliary setpoint [Hz]

50.0

P412

(P) Setpoint process controller [V] 5.0

S

P413

(P) PID control P comp. [%]

10.0

S

P414

(P)

PID control I-component [%/ms]

10.0

S

P415

(P)

PID control D-component [%/ms]

1.0

S

P416

(P) Ramp time PI setpoint [s]

2.0

S

P417

(P) Analog output offset 1 [V]

0.0

S

P418

(P) Function analog output 1

0

P419

(P) Scaling of analog output 1 [%] 100

P420

Digital input 1 (DIN1)

1

P421

Digital input 2 (DIN2)

2

P422

Digital input 3 (DIN3)

8

P423

Digital input 4 (DIN4)

4

P424

Digital input 5 (DIN5)

0

P425

Digital input 6 (DIN6)

0

P426

(P) Emergency stop time [s]

0.10

P427

Emerg. stop Fault

0

S

P428

(P) Automatic starting

0 (off)

S

P429

(P) Fixed frequency 1 [Hz]

0.0

P430

(P) Fixed frequency 2 [Hz]

0.0

P431

(P) Fixed frequency 3 [Hz]

0.0

P432

(P) Fixed frequency 4 [Hz]

0.0

P433

(P) Fixed frequency 5 [Hz]

0.0

P434

(P) Relay 1 function (K1)

1

P435

(P) Relay 1 scaling [%]

100

P436

(P) Relay 1 hysteresis [%]

10

S

P441

(P) Relay 2 function (K2)

7

P442

(P) Relay 2 scaling [%]

100

P443

(P) Relay 2 hysteresis [%]

10

S

P450

(P) Relay 3 function (DOUT1)

0

P451

(P) Relay 3 scaling [%]

100

P452

(P) Relay 3 hysteresis [%]

10

S

P455

(P) Relay 4 function (DOUT2)

0

P456

(P) Relay 4 scaling [%]

100

P457

(P) Relay 4 hysteresis [%]

10

S