Parameter
No. [Array]
Name
Factory
setting
Super-
visor
Setting after commissioning
P 1
P 2
P 3
P 4
P211
(P) Dynamic boost [%]
100
S
P212
(P) Slip compensation [%]
100
S
P213
(P) Adjustment of ISD control [%] 100
S
P214
(P) Torque precontrol [%]
0
S
P215
(P) Boost precontrol [%]
0
S
P216
(P) Time boost precontrol [s]
0.0
S
P217
(P) Oscillation damping [%]
10
S
P218
(P) Modulation depth [%]
100
S
P219
Auto. flux optimisation [%]
100
S
P220
(P) Parameter identification
0
*) dependent on FI power or P200/P220
CONTROL PARAMETER Encoder input, only SK 520E/53xE
P300
(P) Servo Mode [On / Off]
0
P301
Incremental encoder
6
P310
(P) Speed controller P [%]
100
P311
(P) Speed controller I [%/ms]
20
P312
(P)
Torque current controller P [%]
200
S
P313
(P)
Torque current controller I [%/ms]
125
S
P314
(P) Motor current control limit [V]
400
S
P315
(P) Field current controller P [%]
200
S
P316
(P)
Field current controller I [%/ms]
125
S
P317
(P)
Limit, field current controller [V]
400
S
P318
(P)
Field weakening controller P [%]
150
S
P319
(P)
Field weakening controller I
[%/ms]
20
S
P320
(P) Field weakening limit [%]
100
S
P321
(P)
Speed control I ventilation time
0
S
P325
Function encoder
0
P326
Encoder conversion
1.00
P327
Speed slip error [rpm]
0 (off)
P328
Speed slip delay [rpm]
0 (off)
CONTROL TERMINALS
P400
(P) Function analog input 1
1
P401
Mode analog in. 1
0
S
P402
Adjustment 1: 0% [V]
0.0
S
P403
Adjustment 1: 100% [V]
10.0
S
P404
Analog input filter 1 [ms]
100
S
P405
(P) Function analog input 2
0
P406
Analog input mode 2
0
S