beautypg.com

Other optional modules, Installing, Uss bus modules and modbus rtu – NORD Drivesystems BU0540 User Manual

Page 34: Installing the technology unit

background image

SK 500E – Brief instructions for frequency inverters

34

BU 0540 GB-1013

Note

USS Bus modules and Modbus RTU

No optional modules are required for communication via USS or Modbus RTU.

The USS protocol is integrated into all SK 5xxE series devices. An interface is available via terminal X11, or if
present, also via X7:73/74.

Modbus RTU is only available with version SK 54xE or higher. For this, the same interfaces as for USS apply.

A detailed description of both of these protocols can be found in Manual BU 0050.

Other optional modules

Module

Interface

Data

Part No.

Document

SK EBGR-1

Electronic brake
rectifier

Extension for direct control of an electro-
mechanical brake, IP20, snap-on rail
mounting

19140990

TI 19140990

SK EBIOE-2

IO extension

Extension with 4 DIN, 2 AIN, 2 DOUT and
1 AOUT, IP20, snap-on rail mounting,
SK 54xE and higher

275900210

TI 275900210

Table 9: Overview of technology units, other optional modules

Pos : 88 /Anl eitungen/ 3. /4. Anz eige und Bedienung [ BU 0500 / BU 0200] /SK 5xxE/ 3. 2 Übersic ht der Technologieboxen - 2- Mont age @ 1\ mod_1340712929975_388. doc x @ 28340 @ 5 @ 1

Installing

Note

Installing the technology unit

Modules should not be inserted or removed unless the device is free of voltage. The slots may only be used for
the intended modules.

Installation of a technology unit separate from the frequency inverter is not possible. It must be connected directly
to the frequency inverter.

The technology units must be installed as follows:

1. Switch off the mains voltage, observe the

waiting period.

2. Push the control terminals cover down

slightly or remove.

3. Remove the blank cover, by loosening the

release on the lower edge and pulling off
with an upward turning movement. If
necessary, the attachment screw next to the
release must be removed.

4. Hook the technology unit onto the upper edge slots and press in lightly until it engages.

Ensure full contact with the connector strip and fasten with the screws if necessary (separate
packet).

5. Close the control terminal cover again.