Clearing transactions from keypad memory, System reset, Mileage type – Badger Meter Fluid Management System User Manual
Page 16: Mileage information, Clearing transactions from keypad memory 16, System reset 16, Mileage type 16, Mileage information 16, Clear transacts yes / no, Print wo? yes / no

Fluid Management System Standalone Keypad
Clearing Transactions from Keypad Memory
•
Removes all transactions (Dispense Orders) previously recorded in memory
•
Clear transactions erases WO results data
Clear Transacts
YES / NO
Use the Scroll key to move the cursor to either YES or NO and press
Enter
Print WO?
YES / NO
•
If you select YES and the external printer is enabled (refer to
), the display asks if you want to
print the WO results
Confirm Clear
YES / NO
•
If you select YES and the external printer is not enabled, you are
asked to confirm the clear
•
If you select NO, the menu advances to the System Reset screen
System Reset
The System Reset allows a supervisor to reset all configuration parameters to default values
System Reset
YES / NO
1 Use the Scroll key to move the cursor to either YES or NO
Confirm Reset
YES / NO
a If you select YES, the keypad asks you to Confirm Reset
b If you select NO, the keypad advances to the Mileage Type
screen
2 Press Enter
Mileage Type
The Mileage Type allows a supervisor to select how vehicle mileage is stored in the keypad The options are KM (default)
and MILES
Mileage Type
KM / MILES
1 Use the Scroll key to move the cursor to either KM or Miles
2 Press Enter to advance to the Mileage Info screen
Mileage Information
The Mileage Information screen selects the option to collect vehicle mileage information for each dispense order The options
are YES and NO (default)
Mileage Info
YES / NO
1 Use the Scroll key to move the cursor to either YES or NO
2 Press Enter to advance to the Registration Information screen
Page 16
August 2012