West Control Solutions CALogix User Manual
Page 10
![background image](/manuals/370862/10/background.png)
EXAMPLE CIRCUIT
The circuit below shows an example applicaion which includes a base-unit that has one PID module and one logic module
fitted.
FS1 Fuse = 1A time lag type to IEC127. CSA/UL rating 250V
FS2 Fuse = 2A time lag type to IEC127. CSA/UL rating 250V
FS3 Fuse = High rupture capacity (HRC). Suitable for maximum rated load current
S1 switch = IEC/CSA/UL approved disconnection device must be used
It is strongly recommended that the power supply zero volts and all logic module zero volts are common to prevent ground
loops.
INPUT SENSOR SELECTION
* Note
: Type-B accuracy not specified below 100°C/212°F
Thermocouple type
Description
Sensor Range (°C)
Sensor Range (°F)
B
Pt-30% Rh/Pt-6%Rh
0 to1800°C*
32 to 3272°F*
E
Chromel/Con
0 to 600°C
32 to 1112°F
J
Iron/Constantan
0 to 800°C
32 to 1472°F
K
Chromel/Alumel
-50 to 1200°C
-58 to 2192°F
L
Fe/Konst
0 to 800°C
32 to 1472°F
N
Nicrosil/NiSil
-50 to 1200°C
-58 to 2192°F
R
Pt-13%Rh/Pt
0 to 1600°C
32 to 2192°F
S
Pt10%Rh/Pt
0 to 1600°C
32 to 2192°F
T
Copper/Con
-200 to 250°C
-273 to 482°F
Resistance Thermometer
rtd 2/3 wire
Pt100/RTD-2/3
-200 to 800°C
-273 to 1472°F
Page 10 of 44