Measurement setting, Setting item details of setting – KYORITSU 6310 Quick Manual User Manual
Page 15

KEW6310
Measurement Setting
KEW6310
−
13 −
Measurement Setting
Setting Item
Details of Setting
W╱Wh╱
DEMAND*
W
Instantaneous/avg/max/min values ON╱OFF
Wh
Detailes
Target demand
1.000mW~999.9TW (
300.0kW )
Demand inspection cycle
Shorter than intervals, 3 different cycles are
available. ( 10 min )
WAVE
Range* Save item
V
ON╱OFF
A
Harmonic
Analysis*
THD (total harmonic distortion) caluculation
THD-F (fundamental wave basis) /
THD-R (total RMS basis)
Allowable range
Default value ╱Customization
MAX HOLD
ON╱OFF
Save item V
ON╱OFF
A
QUALITY
Swell/ Dip/ Int
measurment
V_Reference
70~1000V( 100V )
Transient
Selectable ranges for threshold vary depending
on the selected reference voltages.
V_Reference 70~150V 151~300V 301~600V 601~1000V
Transient
(selectable range)
50~310
Vpeak(210)
90~630
Vpeak
170~1270
Vpeak
340~2000
Vpeak
Swell
100~200% against reference voltage ( 110% )
Dip
5~100% against reference voltage ( 90% )
Int
5~98% against reference voltage ( 10% )
Hysteresis
1~10% against reference voltage ( 5% )
Trigger point
Past:0~200, Next:200~0 (
100 each)
Transient
measurement
Voltage range
150V
300V
600V
1000V
Threshold value
(selectable range)
50~310
Vpeak
90~630
Vpeak
170~1270
Vpeak
340~2000
Vpeak
(
1415 )
Hysteresis
1~10% against Voltage Range ( 5% )
Trigger point
Past:0~200, Next:200~0 (
100 each)
Inrush current
measurement
Clamp
8128╱8127╱8126╱
8125 ╱8124╱8129
╱
8146╱8147╱8148╱8141╱8142╱8143
A Range
100.0m╱500.0m╱1╱5╱10╱20╱50╱100
╱
200 ╱300╱500╱1000╱3000╱AUTO
Reference current
(selectable range)
Selectable within 10%~100% of Current
Ranges ( 200A )
Filter
ON╱ OFF
Threshold value
100~200% against reference current ( 110% )
Hysteresis
1~10% against reference current ( 5% )
Data trigger point
Past:0~200, Next:200~0 ( 100 each)
Unbalance ratio Output threshold
1~20%( 3% )
Flicker
V Range
150V
300V
600V
Filter coefficient
230V lamp
120V lamp
Output item
Pst(1min) ╱Pst╱Plt
Output Threshold
0.8~20.0 (1.0)
Capacitance
Target power factor
0.5~1( 1.000 )
* Default values are highlighted in gray
.