Type BM90 / L
RZV15
RZT15
RZV15T
BM90E/ LE
RXV15
RXT15
RXV15T
Temperature
Uncompensated
Compensated
Uncompensated
Compensation
Frequency (in KHz)
41.50
41.50
41.50
Beam Angle at 3dB
10 degrees
10 degrees
10 degrees
Body Material
C P V C
C P V C
C P V C
Face Material
Urethane
Urethane
Teflon
Process Temperature *
-40 to + 90 deg C
-40 to + 90 deg C
-20 to +90 deg C
Protection
IP68
IP68
IP68
Weight (Kg)
2.00
2.00
3.00
6. Technical Data Level-Sonic
6.1.
Converter
BM90 / BM90 L
BM90 E / BM90 LE
Enclosure
IP65 Aluminium
NORYL DIN43700. IP55 to front of panel.
IP20 behind panel.
Dimensions
206 (8.11") x 326 (12.83") x 123 (4.84")
144H X 96W X 140D (mm).
Weight
4 Kg (8.8 lb)
1.75Kg
Power Supply
110/230 V selectable, 50/60 Hz, 10 VA
110/230Vac + 10% selected automatically.
12 V or 24 VDC not selectable 6 W
50/60Hz, 12VA, 24Vdc + 25%
Nominal voltages +/- 10 %
- 10%, 9W. Separate terminals.
Fuse Rating
125 mA (slow blow) AC
F2 T160mA for ac supply
250 mA @ 24 V DC
F1 T315mA for 24Vdc supply
500 mA @ 12 V DC
F3 & F4 T80mA
Range
Up to 10 m (32.8 feet) and up to 15 metres liquids and solids with L.
Accuracy
+/- 0.25 % of measured distance at
+ 0.25% of measured distance from the
constant temperature
transducer at constant temperature of 20 C.
Ambient Temp.
- 20 C to + 50 C (- 4 F to + 122 F)
-40 deg C to + 70 deg C.
Calibration
Integral keypad with security code
5 X 4 integral keypad with security code.
Resolution
2 mm (0.08 ") or 0.1 % of range (set at Pr.3)
2mm or 0.1% of range, whichever is the
whichever is greater
greater.
Analogue Output
Opto isolated 4-20 mA or
4-20mA into 750 Ohms. 16 bit. Short circuit
0-20 mA into 750 ohms
protected and opto-isolated on ac powered
Short circuit protected
units. Not opto-isolated on 24Vdc units.
Maximum allowable degradation of signal 2%
under extremes of transient and constant con-
ducted immunity tests to EN50082.
Relay Outputs
5 multifunction SPDT relays
5 multi-function SPDT relays rated
rated 5 A/230 V a.c resistive
8A/230Vac/30Vdc resistive, with gold con
tacts.
Indication
Integral 4 digit LCD, 12 mm (0.47") high
Integral, 4 digit LCD, 12mm high characters.
characters 5 red LED’s to indicate relay status
5 red LED’s to indicate relay status.
Failsafe
High, low, hold (Pr.23 to 29)
High, Low, Hold
Damping
Fully adjustable (Pr.7)
Fully adjustable
Blanking
Fully adjustable (Pr.5) min 0.3 m (11.82 ")
Fully adjustable
Optional Temp.
Reduces ambient temperature errors from
sensor
0.17 % / 1 C of measured distance to
0.01 % / 1 C (34 F)
6.2. Transducer
NOTE: *All the above transducers can be approved for use in Hazardous Areas, Zones 1 & 2 but Ambient
Temperature limited to: -20 to + 60 deg C. CENELEC: EExm II T6 CERTIFICATE NO: 93C.108.020X
CE approved - EMC tested in accordance with EN50081 & EN50082
Parts 1 & 2
Low voltage directive, EN61010