beautypg.com

Alternative mounting arrangements for transducer – KROHNE BM 90 EN User Manual

Page 12

background image

12

2.2.1. Alternative mounting arrangements for transducer

FLEXIBLE OR RIGID
CONDUIT.

BRACKET.

UNDER FLANGE.

INTEGRAL FLANGE WITH PTFE FACE.

SLIP-ON FLANGE.

ISOLATION KIT.

ISOLATION

KIT.

OPTIONAL

ISOLATION KIT

Do not mount transducers incorporating temperature

compensation in direct sunlight.

Do not over-tighten the bolts on flange construction trans-

ducers.

Flange transducers are not pressure rated and are suit-

able only for atmospheric pressure.

CENELEC approved transducers must be mounted and

wired in accordance with the appropriate National

Standards concerning installation in hazardous environ-

ments.

For differential applications mount both transducers at the

same height above the zero datum point.

For open channel flow applications the transducer must

be mounted upstream of the flume or weir as detailed in

BS3680 (usually 3 or 4 times maximum head).