KROHNE VFM 3100 EN User Manual
Page 24
24
NOTE: If the User Information is not supplied with the purchase order,
the following default data for a LIQUID will reside in the database.
Parameter
Metric
U.S.
Tag
blank
blank
Flow Units
Nm
3
/hr
SCF/hr
Total Units
Nm
3
SCF
Fluid Type
Gas (Air)
Gas (Air)
Process Temperature
20 ˚C
70 ˚F
Process Density
9.546 kg/m
3
0.5858 lb/ft
3
Base Density
1.293 kg/m
3
0.07634 lb/ft
3
Process Viscosity
0.0185 cP
0.0186 cP
Upper Range Value
Upper Range Limit for VFM 3100 Size
Upper Range Limit for VFM 3100 Size
Parameter
Metric
U.S.
Tag
blank
blank
Flow Units
kg/hr
lb/hr
Total Units
kg/hr
lb/hr
Fluid Type
Steam (saturated)
Steam (saturated)
Process Temperature
175 ˚C
350 ˚F
Process Density
4.618 kg/m
3
0.2992 lb/ft
3
Base Density (N/A)
0.5977 kg/m
3
0.03730 lb/ft
3
Process Viscosity
0.0149cP
0.0150 cP
Upper Range Value
Upper Range Limit for VFM 3100 Size
Upper Range Limit for VFM 3100 Size
If the process fluid is not LIQUID, changing the fluid type to GAS
or STEAM will automatically bring up the appropriate default set
shown below.
Parameter
Metric
U.S.
Tag
blank
blank
Flow Units
l/min
USgpm
Total Units
l
USgal
Fluid Type
Liquid (water)
Liquid (water)
Process Temperature
20 ˚C
70 ˚F
Process Density
998,2 kg/m
3
62.301 lb/ft
3
Base Density
999.2 kg/m
3
62.374 lb/ft
3
Process Viscosity
1.002 cP
0.9753 cP
Upper Range Value
Upper Range Limit for VFM 3100 Size
Upper Range Limit for VFM 3100 Size