NOTE: If the User Information is not supplied with the purchase order,
the following default data for a LIQUID will reside in the database.

Parameter

Metric

U.S.

Tag

blank

blank

Flow Units

Nm

3

/hr

SCF/hr

Total Units

Nm

3

SCF

Fluid Type

Gas (Air)

Gas (Air)

Process Temperature

20 ˚C

70 ˚F

Process Density

9.546 kg/m

3

0.5858 lb/ft

3

Base Density

1.293 kg/m

3

0.07634 lb/ft

3

Process Viscosity

0.0185 cP

0.0186 cP

Upper Range Value

Upper Range Limit for VFM 3100 Size

Upper Range Limit for VFM 3100 Size

Parameter

Metric

U.S.

Tag

blank

blank

Flow Units

kg/hr

lb/hr

Total Units

kg/hr

lb/hr

Fluid Type

Steam (saturated)

Steam (saturated)

Process Temperature

175 ˚C

350 ˚F

Process Density

4.618 kg/m

3

0.2992 lb/ft

3

Base Density (N/A)

0.5977 kg/m

3

0.03730 lb/ft

3

Process Viscosity

0.0149cP

0.0150 cP

Upper Range Value

Upper Range Limit for VFM 3100 Size

Upper Range Limit for VFM 3100 Size

If the process fluid is not LIQUID, changing the fluid type to GAS
or STEAM will automatically bring up the appropriate default set
shown below.

Parameter

Metric

U.S.

Tag

blank

blank

Flow Units

l/min

USgpm

Total Units

l

USgal

Fluid Type

Liquid (water)

Liquid (water)

Process Temperature

20 ˚C

70 ˚F

Process Density

998,2 kg/m

3

62.301 lb/ft

3

Base Density

999.2 kg/m

3

62.374 lb/ft

3

Process Viscosity

1.002 cP

0.9753 cP

Upper Range Value

Upper Range Limit for VFM 3100 Size

Upper Range Limit for VFM 3100 Size