KROHNE VFM 3100 EN User Manual
Page 15
Table 5. Preparation of Remote Signal Cable (Electronics End)
15
1. Slide the knurled nut and then the rubber bushing onto
outer jacket of cable as shown at right. Next, remove outer
polyethylene jacket of cable to dimension shown.
2. Cut and remove braided copper shield to dimension shown
at right. This will expose the barrier (plastic) tape and foil
mylar that encloses the conductors.
3. Cut and remove the barrier tape, foil mylar and fillers to
dimension shown at right. This will expose two twisted
pairs of conductors (brown-yellow, orange-red) and an
uninsulated drain wire. The barrier tape under the copper
braid prevents the drain wire from shorting to the copper
braid shield.
Electronics End (Electronic Housing End) Procedures
Outer polyethylene
jacket
Outer polyethylene
jacket
Outer polyethylene
jacket
203 mm (8.0 in)
Knurled nut
Rubber bushing
Copper braid
178 mm (7.0 in)
25 (1.0)
Knurled nut
Rubber bushing
Copper braid
Barrier tape and foil mylar
Knurled nut
Rubber bushing
Copper braid
Barrier tape and foil mylar
Two twisted pairs
Uninsulated drain wire
25 (1.0)
40 (1.5)
4. Cut off drain wire at end of barrier tape and foil mylar as
shown ar right. It is not used at this end.
5. Apply shrink tubing or electrical tape to end of barrier tape
and foil mylar at location shown at right. Note that the shrink
tube or tape covers end of barrier tape and mylar as well as
a portion of the 2 twisted pairs of wires. This will prevent the
barrier tape and foil mylar from unwrapping.
6. Cut and strip ends of the two twisted pairs to dimension
shown at right. Label outer cable jacket ”Electronic End”
to avoid confusion during installation. Cable is now ready
for installation.
Knurled nut
Copper braid
Barrier tape and foil
mylar
cut off
here
Two twisted pairs
Outer polyethylene
jacket
Knurled nut
Knurled nut
Rubber bushing
Rubber
bushing
Shrink tube or
electrical tape
cut and strip 4 places
Copper braid
do not tape
Copper braid
do not tape
Label cable
jacket
Electronic
end
Barrier tape
and foil mylar
Barrier tape and foil mylar
Shrink tube or
electrical tape
Two twisted pairs
Outer polyethylene
jacket
Two twisted pairs
Rubber bushing