Description: Operation is identical to OUTPut:STATe command (PAR. B.40) and is provided for compatibility with
other vendors products.
B.22
LIST:CURRent
COMMAND
LIST:CURR
Syntax:
Short Form: LIST:CURR[:LEV]
Long Form: LIST:CURRent[:LEVel]
Description: Sets the current (Amps) value for the memory location selected by LIST:IND. If the value is out of
the acceptable current range for the power supply model, an error message: -222,"Data out of range"
is posted in the output queue. The current value is stored in non-volatile memory and is retained when
the power supply is turned off. Related Commands: LIST:IND. LIST:IND?, LIST:CURR?. (See exam-
ple, Figure B-4.)
B.23
[SOUR:]LIST:CURRent?
QUERY
LIST:CURR?
Syntax:
Short Form: LIST:CURR[:LEV]?
Long Form: LIST:CURRent[:LEVel]?
Return Value:
Description: Returns current value (Amps) stored in indexed memory location selected by LIST:IND. Related
Commands: LIST:IND. LIST:IND?, LIST:CURR. (See example, Figure B-4.)
B.24
[SOUR:]LIST:CURRent:PROTect
COMMAND
LIST:CURR:PROT
Syntax:
Short Form: LIST:CURR:PROT
Description: Sets the current protection (Amps) value for the memory location selected by LIST:IND. If the
value is out of the acceptable current range for the power supply model, an error message: -222,"Data
out of range" is posted in the output queue. The current value is stored in non-volatile memory and is
retained when the power supply is turned off. Related Commands: LIST:IND. LIST:IND?,
LIST:CURR:PROT?. (See example, Figure B-4.)
FIGURE B-4. USING LIST COMMANDS AND QUERIES
LIST:IND 21
Selects memory location 21.
LIST:IND?
Returns 21.
LIST:CURR 2.35E-1
Sets output current value of memory location 21 to 0.235A.
LIST:CURR?
Returns 2.35E-1.
LIST:CURR:PROT 1.67E+1
Sets output current value of memory location 21 to 16.7A.
LIST:CURR:PROT?
Returns 1.67E+1.
LIST:VOLT:PROT 2.77E+1
Sets voltage protection value of memory location 21 to 27.7V.
LIST:VOLT:PROT?
Returns 2.77E+1.
LIST:DWEL 0.6
Sets memory location 21 time value to 0.6 second. During program
execution, after parameters specified by memory location 21 have
been applied for 0.6 second, power supply will switch to parameters
specified by memory location 21 sequence number.
LIST:SEQ:NEXT 39
Sets memory location sequence number to 39. During program
execution, when memory location 21 is complete, the next location
to be executed will be 39.
LIST:SEQ:NEXT?
Returns 39.
LIST:IND 22
Selects memory location 22 .
LIST:IND?
Returns 22.
LIST:VOLT 1.256E+2
Sets output voltage value of memory location 22 to 125.6V.
LIST:VOLT?
Returns 1.256E+2.
LIST:SEQ:STAR 21
Sets memory location 21 as the starting location for executing a
program.
LIST:SEQ:STAR?
Returns 21.
PROG:SEL:STAT RUN
Sequence starting at location 21 and ending at location 22 will be run
continuously
PROG:SEL:STAT STOP
Programmed sequence stops running.