Table 1-3. abc specifications, Abc specifications -2 – KEPCO ABC-DM SERIES User Manual
Page 16
1-2
ABCOPR040104
TABLE 1-3. ABC SPECIFICATIONS
SPECIFICATION
RATING/DESCRIPTION
CONDITION
INPUT CHARACTERISTICS
a-c Voltage
nominal
100/120/220/240V a-c
Single phase
range
85-264V a-c
Wide range
Frequency
nominal
50-60Hz
>63Hz Input leakage current
exceeds specifications
range
47-63Hz (400Hz)
Current
85V a-c
1.8A
Maximum at
100W output
120V a-c
1.3A
240V a-c
0.65A
264V a-c
0.60A
Initial turn-on surge
5A peak for <150 usec
85-264V a-c, 0-100% load
Power Factor (min)
120V
0.99
100% load
240V
0.97
EMC immunity to:
Radiated RF
EN 61000-4-3
level 3
Magnetic Field
EN 61000-4-8
level 4
Electrostatic discharge
EN 61000-4-2
level 2: contact,
level 3: 8KV air discharge
Conducted RF
EN 61000-4-6
level 3
Electrical fast transient
EN 61000-4-4
level 3
Surges
EN 61000-4-5
level 4
EMC Emissions
Conducted
EN 55022 Class B
0.15-30 MHz
Radiated
EN 55022 Class B
30-1000 MHz
Harmonics
Conducted
EN 61000-3-2
0-2 KHz
Leakage current
120V a-c
<0.25mA
Source frequency in
47-63Hz range
240V a-c
<0.5mA
Circuit type
PFC
Flyback converter
Output
Forward converter
Switching Frequency
100KHz
OUTPUT CHARACTERISTICS
Type of Stabilizer
Automatic crossover
Voltage/Current
Adjustment range
0 to 100% of rating
Voltage/Current
Source effect
Voltage
<0.01% E
O
max
Nominal ±15%
of input voltage
Current
<0.01% I
O
max
Load effect
Voltage
<0.01% E
O
max
0 to 100% load change
Current
<0.02% I
O
max
Temperature effect
Voltage
<0.01% E
O
max
Per degree C
(0 to 50° C)
Current
<0.01% I
O
max
Time effect
Voltage
<0.01% E
O
max
0.5-8.5 hours
Current
<0.01% I
O
max
Error sense
0.5V per wire
Voltage allowance
Isolation voltage
500V d-c or peak
Output to ground