EN - 24
5.2.4. Single phase system – Screens sequence
12/09/2006 – 16:55:10
PHASE 1 RMS VALUES – Page x/y
V1N
VNPE
Freq
I1
Patt1
Preatt1
Papp1
Pf1
CosPhi1
=
=
=
=
=
=
=
=
=
0.0 V
0.0 V
0.0 Hz
0.0 A
0.0 W
0.0 VAr
0.0 VA
0.00i
0.00i
PAGE
SCOPE
HARM
VECTORS
PARAMETERS CAPTION:
V1N
Phase-Neutral voltage L1 phase
VNPE
Neutral-Ground voltage
Freq
Frequency
I1
Current on L1 phase
Pact1
Active Power L1 phase
Preact1
Reactive Power L1 phase
Papp1
Apparent Power L1 phase
Pf1
Power factor L1 phase
CosPhi1
Power factor between fundamental of
voltage L1 and current L1
Fig. 39: Page of numerical values
25/01/2013 – 16:55:10
TOT. ENERGY CONSUMPTION – Page x/y
Eact =
0
kWh
Ppeak =
0
kW
Date Ppeak
:
-- / -- / -- 00:00:00
Start rec.
:
-- / -- / -- 00:00:00
Stop rec.
:
-- / -- / -- 00:00:00
Rec. Time
:
- - -
Int. Per.
:
- - -
Rec: - -
PAGE
SCOPE
HARM
VECTORS
PARAMETERS CAPTION:
Eact
Total active energy consumed when starting
recording.
Ppeak
Maximum peak of consumed active power.
Date Ppeak
Date and time in which the peak occurred.
Start rec.
Date when recording was started.
Stop rec.
Date when recording was stopped.
Rec. Time
Time elapsed from Rec Start.
Int. Per.
Value of the set integration period.
Rec
Number of the recording in progress
Fig. 40: Consumed energy page
CAUTION
The Total Consumed Energy page is shown only if the instrument has been
set for the Recording of the General Parameter Total “Active Power &
Energy” (see § 5.4.6.1). Values will be shown only during or at the end of a
recording and zeroed upon starting a new recording or when the instrument
is switched off
25/01/2013 – 16:55:10
TOT. ENERGY PRODUCTION – Page x/y
Eact =
0
kWh
Ppeak =
0
kW
Date Ppeak
:
-- / -- / -- 00:00:00
Start rec.
:
-- / -- / -- 00:00:00
Stop rec.
:
-- / -- / -- 00:00:00
Rec Time
:
- - -
Int. Per.
:
- - -
Rec: - -
PAGE
SCOPE
HARM
VECTORS
PARAMETERS CAPTION:
Eact
Total active energy produced when starting
recording.
Ppeak
Maximum peak of produced active power.
Date Ppeak
Date and time in which the peak occurred.
Start rec.
Date when recording was started.
Stop rec.
Date when recording was stopped.
Rec Time
Time elapsed from Rec Start.
Int. Per.
Value of the set integration period.
Rec
Number of the recording in progress
Fig. 41: Producted energy page
CAUTION
The Total Produced Energy page is shown only if recording parameter “Co-
generation” has been set in the instrument (see § 5.4.5) and if general
parameter Total “Active Power & Energy” has been selected (see § 5.4.6.1).
Values will be shown only during or at the end of a recording and zeroed
upon starting a new recording or when the instrument is switched off.