beautypg.com

GW Instek PST series Programming Manual User Manual

Page 9

background image

PST & PSS & PSH SERIES PROGRAMMABLE POWER SUPPLY

PROGRAMMER MANUAL

⎯ 15 ⎯

:OUTPut:PROTection:CLEar

Clears over-voltage and over-current and
over temperature protection error message.

:OUTPut:STATe

Sets the output state on or off.

:OUTPut:STATe ?

Returns the output state on or off.

Remark:

The mark “★1” means the for PSS and PSH series can only be 1.

The mark “★2” means the PSS and PSH series do not have the function.

z Status Commands

Table 3 lists the status commands that set and query the various
registers and queues that make up the status and event structure of the
programmable power supply.

Table 3: Status Commands

*CLS

Clears the status data structures.

*ESE

Sets the Event Status Enable Register
(ESER).

*ESE?

Returns contents of Event Status Enable
Register (ESER).

*ESR?

Returns and clear the contents of Standard
Event Status Register (SESR).

*SRE

Sets contents of Service Request Enable
Register(SRER).

PST & PSS & PSH SERIES PROGRAMMABLE POWER SUPPLY

PROGRAMMER MANUAL

⎯ 16 ⎯

*SRE?

Returns contents of Service Request
Enable Register (SRER).

*STB?

Reads Status Byte Register (SBR).

:STATus:OPERation:COND
ition ?

Returns the contents of the OPERation
condition register. Returns NR1.

:STATus:OPERation:ENAB
le

Sets the contents of the enable mask for the
OPERation event register.

:STATus:OPERation:ENAB
le ?

Returns the contents of the enable mask for
the OPERation event register. Returns NR1.

:STATus:OPERation:EVEN
t ?

Query the contents of the OPERation Event
register.

:STATus:PRESet

Presets the OPERation and QUEStionable
status registers.

:STATus:QUEStionable:CO
NDition ?

Returns the contents of the OPERation
condition register. Returns NR1.

:STATus:QUEStionable:EN
ABle

Sets the contents of the enable mask for the
QUEStionable enable register.

:STATus:QUEStionable:EN
ABle ?

Query the contents of the Questionable
Enable register.

:STATus:QUEStionable:EV
ENt ?

Query the contents of the QUEStionable
Event register.

z Miscellaneous Commands

Table 4 lists the miscellaneous commands that control general
housekeeping functions of the programmable power supply.

This manual is related to the following products: