GW Instek PST series Programming Manual User Manual
Page 19

PST & PSS & PSH SERIES PROGRAMMABLE POWER SUPPLY
PROGRAMMER MANUAL
⎯ 35 ⎯
the value of START.
Returns:
Examples:
SYSTem:AUTO:END 8
sets auto end on from the memory of location 8
of the current device.
If the command SYSTem:AUTO:END? Returns 99, means set the
section 99 as the end.
SYSTem:AUTO:STARt
Function:
Set the start memory section for auto execute continuously
(The PSS and
PSH series do not have this function.)
Syntax:
SYSTem:AUTO:STARt
SYSTem:AUTO:STARt?
is in the range from 0 through 99 and must be small or equal to
the value of END.
Returns:
Examples:
SYSTem:AUTO:STARt 0
sets auto start on from the memory of
location 0 of the current device.
If the command SYSTem:ATUO:STARt? Returns 2, means set the
section 2 as the start.
PST & PSS & PSH SERIES PROGRAMMABLE POWER SUPPLY
PROGRAMMER MANUAL
⎯ 36 ⎯
SYSTem:AUTO:STATe
Function:
Set or return automatic sequence setting
(The PSS and PSH series do not
have this function.)
Syntax:
SYSTem:AUTO:STATe
SYSTem:AUTO:STATe?
can be 0(OFF) or 1(ON).
Returns:
0|1
Examples:
SYSTem:AUTO:STATe 1
sets auto sequence on.
SYSTem:ERRor?
(query only)
Function:
Query the next error message from the Error/Event queue. The result of
the query is the error number followed by the error text.
Syntax:
SYSTem:ERRor?
Returns:
Examples:
SYSTem:ERRor?
returns 0, “No error”