PST & PSS & PSH SERIES PROGRAMMABLE POWER SUPPLY

PROGRAMMER MANUAL

⎯ 33 ⎯

STATus:QUEStionable:EVENt

(query only)

Function:
Return and clear the contents of the QUEStionable register. The response
is a decimal value that summarizes the binary values of the set bits.

Syntax:

STATus:QUEStionable:EVENt?

Returns:

Examples:

STATus:QUEStionable:EVENt?

returns 0.

SYSTem:AUTO:CYCLe

Function:

Set or query the number of times of execution (The PSS and PSH series do not
have this function.)

Syntax:

SYSTem:AUTO:CYCLe

SYSTem:AUTO:CYCLe?

is in the range from 0 through 99999 or infinite.

Returns:

Examples:

SYSTem:AUTO:CYCLe 8

sets auto cycle on to repeat the setting 8

times.

SYSTem:AUTO:CYCLe 0

sets auto cycle on to repeat the setting

infinite.
If the command SYSTem:AUTO:CYCLe? Returns 0, means infinite.

PST & PSS & PSH SERIES PROGRAMMABLE POWER SUPPLY

PROGRAMMER MANUAL

⎯ 34 ⎯

SYSTem:AUTO:DELay

Function:
Set the delay time under the current responding memory status

(The PSS

and PSH series do not have this function.)

Syntax:

SYSTem:AUTO:DELay

SYSTem:AUTO:DELay?

is in the range from 1 through 59999, its unit is 100ms.

Returns:

Examples:

SYSTem:AUTO:DELay 1

sets auto delay time at 100ms for the memory

of the specific section.

SYSTem:AUTO:DELay 1000

sets auto delay time at 100 seconds for

the memory of the specific section, no further setting of auto delay will
be done on next memory section until the previous auto delay is fulfilled.
If the command SYSTem:AUTO:DELay? Returns 5, means delay
500ms at the current memory section that displayed on the LCD panel.

SYSTem:AUTO:END

Function:
Set the end memory section for auto execute continuously

(The PSS and

PSH series do not have this function.)

Syntax:

SYSTem:AUTO:END

SYSTem:AUTO:END?

is in the range from 0 through 99 and must be large or equal to