GW Instek PST series Programming Manual User Manual
Page 18

PST & PSS & PSH SERIES PROGRAMMABLE POWER SUPPLY
PROGRAMMER MANUAL
⎯ 33 ⎯
STATus:QUEStionable:EVENt
(query only)
Function:
Return and clear the contents of the QUEStionable register. The response
is a decimal value that summarizes the binary values of the set bits.
Syntax:
STATus:QUEStionable:EVENt?
Returns:
Examples:
STATus:QUEStionable:EVENt?
returns 0.
SYSTem:AUTO:CYCLe
Function:
Set or query the number of times of execution (The PSS and PSH series do not
have this function.)
Syntax:
SYSTem:AUTO:CYCLe
SYSTem:AUTO:CYCLe?
is in the range from 0 through 99999 or infinite.
Returns:
Examples:
SYSTem:AUTO:CYCLe 8
sets auto cycle on to repeat the setting 8
times.
SYSTem:AUTO:CYCLe 0
sets auto cycle on to repeat the setting
infinite.
If the command SYSTem:AUTO:CYCLe? Returns 0, means infinite.
PST & PSS & PSH SERIES PROGRAMMABLE POWER SUPPLY
PROGRAMMER MANUAL
⎯ 34 ⎯
SYSTem:AUTO:DELay
Function:
Set the delay time under the current responding memory status
(The PSS
and PSH series do not have this function.)
Syntax:
SYSTem:AUTO:DELay
SYSTem:AUTO:DELay?
is in the range from 1 through 59999, its unit is 100ms.
Returns:
Examples:
SYSTem:AUTO:DELay 1
sets auto delay time at 100ms for the memory
of the specific section.
SYSTem:AUTO:DELay 1000
sets auto delay time at 100 seconds for
the memory of the specific section, no further setting of auto delay will
be done on next memory section until the previous auto delay is fulfilled.
If the command SYSTem:AUTO:DELay? Returns 5, means delay
500ms at the current memory section that displayed on the LCD panel.
SYSTem:AUTO:END
Function:
Set the end memory section for auto execute continuously
(The PSS and
PSH series do not have this function.)
Syntax:
SYSTem:AUTO:END
SYSTem:AUTO:END?
is in the range from 0 through 99 and must be large or equal to