1. Press Wave key and select Sine
WAVE
2. Press 2 + 5 + 0 + Hz/% key
2
5
0
Hz/%
3. Press Shift + 5 key (Sweep)
SWEEP
5
4. Press SWEEP TIME knob (LIN)
and rotate
SWEEP TIME LIN
Linear Sweep,
1kHz start,
Sine wave 250Hz
OUTPUT
50
Ω
5. Press SWEEP SPAN knob and
rotate
SWEEP SPAN
1. Press Wave key and select
Triangle
WAVE
2. Press 8 + kHz key
8
kHz
3. Press Shift + 5 key (Sweep)
SWEEP
5
4. Pull SWEEP TIME knob (LOG)
and rotate
SWEEP TIME
LOG
Log Sweep,
10kHz start,
Triangle wave
8kHz
OUTPUT
50
Ω
5. Press SWEEP SPAN knob and
rotate
SWEEP SPAN
1. Press Wave key and select Sine
WAVE
2. Press 1 + 0 + kHz key
1
0
kHz
3. Press Shift + .(dot) key (AM)
AM
AM, Internal,
50% modulation,
sine wave 10kHz
OUTPUT
50
Ω
4. Pull SWEEP SPAN knob (AM
%) and rotate
SWEEP SPAN
1. Press Wave key and select Sine
WAVE
2. Press 1 + MHz key
1
MHz
3. Input external modulation signal
(EXT sign appears)
EXT
4. Press Shift + 4 key (FM)
AM
FM, External,
50% deviation,
sine wave 1MHz
OUTPUT
50
Ω
5. Push SWEEP SPAN knob (FM
Dev) and rotate
SWEEP SPAN
(FM Dev)
SFG-2000 Series User Manual
24
1. Press Shift + 1 (Counter)
1
Counter input,
sine wave 1MHz
COUNTER
INPUT
2. The Gate sign flashes when
counted
1. Press Shift + 6 (Store)
STORE
6
2. The “Store” sign appears
3. Enter the memory number (1 ~
10)
Store the setting
to memory No.1
4. The “done” sign appears
1. Press Shift + 3 (Recall)
RECALL
3
2. The “Recall” sign appears
3. Enter the memory number (1 ~
10)
Recall the setting
from memory
No.1
4. The “done” sign appears
Default Setting Contents
Recall default
settings
2
Press the shift key, then 2 to recall the
default setting. The “done” message
appears, followed by display update.
Wave type
Sine wave
Frequency
10.0000kHz
TTL/CMOS
Disabled
−20dB
Disabled
Modulation
Disabled
Sweep mode
Disabled