Triton FT5000 X2 User Manual User Manual
Page 96
522
EJ error
Restart operating system. If the problem persists, it may be necessary to
replace the ATM main board assembly on Xscale systems, or the PC
assembly or hard drive on the xp or 9800 systems..
523
EJ data size error
Restart operating system. If the problem persists, it may be necessary to
replace the ATM main board assembly on Xscale systems, or the PC
assembly or hard drive on the xp or 9800 systems..
524
EJ bad command
Restart operating system. If the problem persists, it may be necessary to
replace the ATM main board assembly on Xscale systems, or the PC
assembly or hard drive on the xp or 9800 systems..
525
EJ invalid ID
Restart operating system. If the problem persists, it may be necessary to
replace the ATM main board assembly on Xscale systems, or the PC
assembly or hard drive on the xp or 9800 systems..
526
EJ device busy
Restart operating system. If the problem persists, it may be necessary to
replace the ATM main board assembly on Xscale systems, or the PC
assembly or hard drive on the xp or 9800 systems..
527
EJ invalid request
Restart operating system. If the problem persists, it may be necessary to
replace the ATM main board assembly on Xscale systems, or the PC
assembly or hard drive on the xp or 9800 systems..
528
EJ sequence error
Restart operating system. If the problem persists, it may be necessary to
replace the ATM main board assembly on Xscale systems, or the PC
assembly or hard drive on the xp or 9800 systems..
529
EJ device offline
Restart operating system. If the problem persists, it may be necessary to
replace the ATM main board assembly on Xscale systems, or the PC
assembly or hard drive on the xp or 9800 systems..
530
EJ EXT error
Restart operating system. If the problem persists, it may be necessary to
replace the ATM main board assembly on Xscale systems, or the PC
assembly or hard drive on the xp or 9800 systems..
531
EJ SOH error
Restart operating system. If the problem persists, it may be necessary to
replace the ATM main board assembly on Xscale systems, or the PC
assembly or hard drive on the xp or 9800 systems..
532
EJ STX error
Restart operating system. I the problem persists, it may be necessary to
replace the ATM main board assembly on Xscale systems, or the PC
assembly or hard drive on the xp or 9800 systems..
533
EJ BCC error
Restart operating system. If the problem persists, it may be necessary to
replace the ATM main board assembly on Xscale systems, or the PC
assembly or hard drive on the xp or 9800 systems..
534
EJ device reset
Restart operating system. If the problem persists, it may be
necessary to replace the ATM main board assembly on Xscale
systems, or the PC assembly or hard drive on the xp or 9800
systems..
535
Card Reader - Data size error
Inspect card reader cabling. Inspect card reader for foreign objects.
Clean the card reader with an approved cleaning device. Clear the
terminal error code. Reboot the ATM. If error persists, replace the
card reader.
536
Card Reader - Device read error
Inspect card reader cabling. Inspect card reader for foreign objects.
Clean the card reader with an approved cleaning device. Clear the
terminal error code. Reboot the ATM. If error persists, replace the
card reader.
537
Card Reader - Invalid Record
Inspect card reader cabling. Inspect card reader for foreign objects.
Clean the card reader with an approved cleaning device. Clear the
terminal error code. Reboot the ATM. If error persists, replace the
card reader.
538
Card Reader - Reader type error
Inspect card reader cabling. Inspect card reader for foreign objects.
Clean the card reader with an approved cleaning device. Clear the
terminal error code. Reboot the ATM. If error persists, replace the
card reader.