C-2
M
ODEL
FT5000 (X2) U
SER
M
ANUAL
I
NTRODUCTION
The security cabinet can be secured using an electronic combination locks. This appendix covers how to
change the combination of either lock. Procedures specific to the electronic lock, such as changing the
battery, are also covered.
O
PERATING
THE
E
LECTRONIC
L
OCK
(L
A
G
ARD
)
The electronic lock combination consists of six digits. Upon arrival, the combination of the lock should
already be preset to 1-2-3-4-5-6.
E
NTERING
THE
C
OMBINATION
1.
Enter the preset combination and check for proper operation. After each keypress, the lock will beep.
After the final digit has been entered, the lock will beep twice, and the open period will begin.
2.
When a valid combination has been entered, the operator will have approximately 4 seconds to open
the lock.
3.
To open the lock, turn the dial clockwise.
4.
After the lock is opened, the cabinet door may be opened.
L
OCKOUT
F
EATURE
The lock includes a ‘Wrong Try Penalty’ lockout feature that prevents entry from unauthorized person-
nel. This feature performs as follows:
•
Entry of four (4) consecutive invalid combinations starts a 5-minute delay period.
-
LED flashes red at ten (10) second intervals.
•
At the end of the delay period, two (2) more consecutive invalid combinations will restart an addi-
tional 5-minute delay.
C
HANGING
THE
C
OMBINATION
To change the combination of the lock, simply follow these directions.
1.
Enter six (6) zeros ‘0’.
2.
Enter the current combination (initially set at 1-2-3-4-5-6).
3.
Enter the new six (6) digit combination twice.
-
If a mistake is made, wait thirty (30) seconds and repeat the first 3 steps.
4.
Test lock combination several times before closing the door. The combination is now changed.
Valid Code Entry - Double signal after valid six (6) digit code is entered.
Invalid Code Entry - Triple signal and old code is still valid.