387
Dispenser offline - error-validating
configuration
Dispenser failed to identify the dispenser type installed.
1. Verify all connectors to the dispenser mechanism.
2. Restart operating system. Clear terminal error code.
3. If error persists, replace the dispenser mechanism or the CMC of an NMD
dispenser
388
Dispenser offline - NMD require Reject
Vault and at least one cassette
Verify that the Reject Vault and one cassette are present in the dispenser
mechanism. Clear terminal error code. If error persists, replace the dispenser
mechanism
389
Dispenser offline. Detected offline error
check op state
Restart the operating system. Verify the error code lights on the dispenser are
operating in proper sequence. Use the NMD test software (available to Triton
Certified Service Technicians) and verify the operational error code of the
dispenser.
390
Dispenser offline - storing configuration Restart the operating system. Verify the error code lights on the dispenser are
operating in proper sequence. Use the NMD test software (avail able to Triton
Certified Service Technicians) and verify the operational error code of the
dispenser.
391
Dispenser sensor failure 2
Access the management function diagnostics menus to verify the operational
error code of dispenser mechanism sensors. Clean sensors as needed.
Replace dispenser components or dispenser if the error persists.
392
Error in last dispense
Check operational error code of dispenser. This problem may be
resolved by replacing the CMC board or by replacing the dispenser
mechanism.
393
Error in double detect 2
394
Purge failed upon power-up
395
Multiple cassette of the same type
NMD dispenser allows for only one of each cassette ID to be installed. Verify
each cassette ID. Replace cassette or Inject New Cassette ID.
396
Dispenser offline – found no reject
bin
500
SPED Read Error
Verify all SPED connections. Restart the operating system. Clear any errors
conditions. Inspect the battery for a voltage reading of greater than 2.8 VDC.
Replace SPED battery is below 2.8 VDC. Replace SPED module if error
persists.
501
SPED invalid return record
Verify all SPED connections. Restart the operating system. Clear
any errors conditions. Inspect the battery for a voltage reading of
greater than 2.8 VDC. Replace SPED battery is below 2.8 VDC.
Replace SPED module if error persists.
502
SPED read type error
Verify all SPED connections. Restart the operating system. Clear
any errors conditions. Inspect the battery for a voltage reading of
greater than 2.8 VDC. Replace SPED battery is below 2.8 VDC.
Replace SPED module if error persists.
503
SPED invalid command
Verify all SPED connections. Restart the operating system. Clear
any errors conditions. Inspect the battery for a voltage reading of
greater than 2.8 VDC. Replace SPED battery is below 2.8 VDC.
Replace SPED module if error persists.
504
SPED invalid return ID
Verify all SPED connections. Restart the operating system. Clear
any errors conditions. Inspect the battery for a voltage reading of
greater than 2.8 VDC. Replace SPED battery is below 2.8 VDC.
Replace SPED module if error persists.
505
SPED device busy
Verify all SPED connections. Restart the operating system. Clear
any errors conditions. Inspect the battery for a voltage reading of
greater than 2.8 VDC. Replace SPED battery is below 2.8 VDC.
Replace SPED module if error persists.
506
SPED invalid request
Verify all SPED connections. Restart the operating system. Clear
any errors conditions. Inspect the battery for a voltage reading of
greater than 2.8 VDC. Replace SPED battery is below 2.8 VDC.
Replace SPED module if error persists.
30