Triton FT5000 X2 User Manual User Manual
Page 102
615
ERR SPED TAMPER STATUS GRID
Inspect cable from main board assembly to the SPED module for
damage. Make sure that the cable is connected at both ends.
Verify that the DC operating voltages are correct. Restart ATM.
Clear the error. If error persists, replace the SPED module.
616
ERR SPED TAMPER STATUS
VOLTAGE
Inspect cable from main board assembly to the SPED module for
damage. Make sure that the cable is connected at both ends.
Verify that the DC operating voltages are correct. Restart ATM.
Clear the error. If error persists, replace the SPED module.
617
ERR SPED SERIAL NUMBER
CHANGE
Inspect cable from main board assembly to the SPED module for
damage. Make sure that the cable is connected at both ends.
Verify that the DC operating voltages are correct. Restart ATM.
Clear the error. If error persists, replace the SPED module.
618
SPED serial number change
Inspect cable from main board assembly to the SPED module for
damage. Make sure that the cable is connected at both ends.
Verify that the DC operating voltages are correct. Restart ATM.
Clear the error. If error persists, replace the SPED module.
619
NMD 100 shutter failed after reset
Inspect cable from Dispenser CMC assembly to the Shutter
Assembly for damage. Make sure that the cable is connected at
both ends. Verify that the DC operating voltages are correct.
Restart ATM. Clear the error. If the Error persists consider replacing
the cable between the Dispenser CMC Board and The Shutter
Assembly, the Shutter Assembly PCB, the Shutter Assembly or the
Dispenser CMC Assembly.
620
NMD 100 shutter OK after reset
To be determined
38