beautypg.com

4 ground speed calibration – Seed Hawk 30 SERIES 2015 User Manual

Page 51

background image

SEED HAWK

®

2015 30 SERIES OPERATOR’S MANUAL – DOMESTIC

46

5.4.4 Ground Speed Calibration

All new systems require a ground speed calibration to ensure accurate area
totals and accurate ground speed readings.

During the calibration the monitor is counting the number of pulses produced
from the drill mounted sensor. The monitor will display the pulses counted in
400 ft. (122m). Choosing this item will allow you to calibrate the ground speed
sensor to a known distance. The default distance is 400 ft. (122m) but this can
be set by the user. To perform a ground speed calibration, determine the dis-
tance to be used and measure out a course.

1. To complete the calibration, mea-
sure a course 400 ft. (122m) long
preferably on level ground with a start
and finish point.  Line up tractor at 
the Start Point. The drill must be in
the down position throughout the
procedure. On the monitor, verify that
the calibration length is 400 ft. (122m).
If not, be sure to correct it. Once the
distance is entered, select “Continue”
and press the

Enter Key.

3. At the end of the 400 ft. (122m)
course, stop the tractor, select
“Complete” and press the

Enter Key.

2. A dialogue box pormpts the user
to start driving

and shows a live count

of wheel pulses recieved. This number
will increase as the user drives the
400 ft. (122m) course.