Manually rebuilding array, 2 manually rebuilding array – LT Security LTN8600 Series NVR (V2.3.2) User Manual
Page 159

User Manual of 9600/8600/7700/7600 Series NVR
159
Figure 10. 18 Set Hot Spare Disk Interface
10.2.2 Manually Rebuilding Array
Purpose:
If you do not enable the Auto-rebuild in Firmware Settings interface (Menu>HDD>RAID>Firmware) or the hot
spare disk has not been configured, then you can rebuild the array manually to restore the array when the virtual
disk is in Degraded status.
Steps:
1.
Enter the Array Settings interface. The disk 3 is lost.
Menu > HDD > RAID > Array
Figure 10. 19 Array Settings Interface
2.
Enter the Virtual Disk interface to check the status of the virtual disk. The virtual disk is in Degraded status.
Figure 10. 20 Virtual Disk Interface
3.
Click Array tab to back to the Array Settings interface and click
to configure the array rebuild.