Access Gateway switches support flow monitors on F_Ports only, and only the ingress port parameter
is supported. For more information on using Flow Monitor features for Access Gateway in Flow Vision,
refer to the Flow Vision Administrator's Guide .

Legacy performance monitoring features

Instead of Flow Monitor, you can use the legacy end-to-end and frame monitoring features available
through Advanced Performance Monitoring (APM). These legacy features are available on platforms
using Fabric OS 7.2 and earlier. The following licenses must be appropriately installed on the AG
switch to use the end-to-end and frame monitors:

APM

Fabric Watch

Use the following Fabric OS commands used to manage APM in switch mode to manage end to end
and frame monitoring in AG mode. Refer to the Fabric OS Command Reference Manual and Fabric
OS Administrator’s Guide for details.

perfAddEEMonitor

perfMonitorClear

perfMonitorShow --class EE

perfResourceShow

perfCfgSave

perfCfgClear

perfCfgRestore

fmmonitor

You can also use Fabric Watch to configure thresholds corresponding to specific frame monitors Refer
to the Fabric Watch Administrator's Guide for details.

End-to-end monitors

End-to-end monitors measure the traffic between a host and target pair by counting the number of
words in Fibre Channel frames for a specified Source ID (SID) and Destination ID (DID) pair. An end-
to-end performance monitor includes these counts:

RX_COUNT - Words in frames received at the port

TX_COUNT - Words in frames transmitted from the port

To enable end-to-end performance monitoring, you must install an end-to-end monitor on an F_Port
using the perfAddEEMonitor command, specifying the SID-DID pair (in hexadecimal). End-to-end
monitoring on N-ports is not supported in AG mode. Complete details of the perfAddEEMonitor
command parameters are provided in the Fabric OS Command Reference Manual .

NOTE
End-to-end monitors are not supported on logical EX, VE, VEX, Mirror, or FCoE ports.

For more information on end-to-end monitoring, including the following topics, refer to the "End-to-end
performance monitoring" section in the Fabric OS Administrator’s Guide :

General feature information

Fabric OS commands for end-to-end monitors

The maximum number of end-to-end monitors per switch model

Setting a mask for a monitor