beautypg.com

Failback policy configurations in access gateway, Failback example – Brocade Access Gateway Administrator's Guide (Supporting Fabric OS v7.3.0) User Manual

Page 70

background image

Failback policy configurations in Access Gateway

The following sequence describes how a failback event occurs:

When an N_Port comes back online, with the Failback policy enabled, the F_Ports that were
originally mapped to it are temporarily disabled.

The F_Port is rerouted to the primary mapped N_Port, and then re-enabled.

The host establishes a new connection with the fabric.

NOTE
The failback period is quite fast and rarely causes an I/O error at the application level.

Failback example

In Example 3, described below, the Access Gateway N_1 remains disabled because the
corresponding F_A1 port is offline. However, N_2 comes back online. See

Failover example

on page

63 for the original failover scenario.

Failback policy configurations in Access Gateway