Supported fabric os commands – Brocade Access Gateway Administrator's Guide (Supporting Fabric OS v7.3.0) User Manual
Page 20
Behavior of sending AG switch and receiving fabric switch with different policies configured
TABLE 2
Fabric switch with device
policy mode ON
Fabric switch with device
policy mode PASSIVE
Fabric switch with device
policy mode OFF
AG switch with
switch policy
mode on
Authorization negotiation -
accept
DH-CHAP/FCAP:
Success - N_Port
Failure - disable
Authorization negotiation -
accept
DH-CHAP/FCAP:
Success - N_Port
Failure - disable
Authorization negotiation -
reject
N_Port without
authentication
AG switch with
switch policy off
No negotiation
No light
No Negotiation
N_Port without authenctication.
No negotiation
N_Port without
authentication
Behavior of sending device (HBA) and receiving AG switch with different policies
configured
TABLE 3
AG switch with device
policy mode ON
AG switch with device
policy mode PASSIVE
AG switch with device
policy mode OFF
HBA authentication enabled Authorization negotiation
- accept
DH-CHAP
Success - F_Port
Failure - disable
Authorization negotiation -
accept
DH-CHAP
Success - F_Port
Failure - disable
Authorization negotiation
- reject
F_Port without
authentication
HBA authenticationdisabled No negotiation
No light
No negotiation
F_Port without
authentication
No negotiation
F_Port without
authentication
Supported Fabric OS commands
All Fabric OS commands for authentication policy apply to AG switches, including the following:
•
authutil -- policy
•
authutil --show
•
authutil --set
•
secauthsecret --set
•
secauthsecret --show
NOTE
Although authutil --authinit is not supported in AG mode, it is supported in native mode.
For more information, refer to the Fabric OS Command Reference .
Supported Fabric OS commands
18
Access Gateway Administrator's Guide
53-1003126-01