Sz sets the recording zone, Sp sets partially expanded recording, Sg sets or copies a message – Yokogawa DR240 User Manual
Page 61: St sets a tag, Sh sets a header, Sj sets a title, Sf sets the format for list printing

6-7
IM DR231-11E
Commands
6
SZ
Sets the recording zone.
Mode
Operation mode
Setting
SZp1, p2, p3
p1
Channel number (001 to 560)
Computation channel number (A01 to A60)
p2
Lower limit of zone (0 to 245 mm, or 0 to
145 mm for the DR130)
p3
Upper limit of zone (5 to 250 mm, or 5 to
150 mm for the DR130)
Example
Set the recording zone of channel 6 in slot 3 of
subunit 4 to 10 to 50 mm.
SZ436, 10, 50
Comments
• Set p2 smaller than p3.
• This is effective for analog recording.
• The optional computation channel number for a
stand-alone model is A01 to A30.
SP
Sets partially expanded recording.
Mode
Operation mode
Setting
SZp1, p2, p3, p4
p1
Channel number (001 to 560)
Computation channel number (A01 to A60)
p2
ON/OFF of partially expanded recording
ON
Performs partially expanded
recording.
OFF
Does not perform partially expanded
recording.
p3
Boundary recording position (1 to 99%)
p4
Boundary value
Example
Partially compress and record channel 6 in slot 3 of
subunit 4 at the boundary recording position of 25%
for the boundary value 0 V.
SP436, 25, 0
Comments
• A waveform can be partially expanded by setting
the set input level (boundary value) as a
percentage of the recording chart (boundary
recording position).
• This is effective for analog recording.
• If contiguous channels are set to p1, the decimal
point in boundary values when the measurement
ranges for set channels differ take the positions
determined for each measurement range (see
Pages 5-7 and 5-8). If the result exceeds the
measurable ranges, an error occurs. For example,
if the channels of measurement ranges 20 mV, 2
V, and type T thermocouple are set to p1 and the
boundary value is set to 10000, the following
applies:
• The boundary value for the channel of the 20
mV
measurement range: 10.000 mV
• The boundary value for the channel of the 2 V
measurement range: 1.0000 V
• The boundary value for the channel of the type
T thermocouple: 1000.0
°
C
Since the measurement range of the type T
thermocouple is -200.0 to 400.0
°
C, an error
occurs. For decimal point positions, see Pages
5-7 and 5-8.
• The optional computation channel number for a
stand-alone model is A01 to A30.
• Set p4 to a value within the recording span, or
within the left/right scale if linear scaling is
applied. It is not possible, however, to set the
recording span nor the left/right scale.
• In the case of power monitor module, if the
settings of the wiring method and the input range
are changed, the partially expanded recording
setting is set to OFF.
SG
Sets or copies a message.
Message setting
Mode
Operation mode
Setting
SGp1, p2
p1
Message number (01 to 20)
p2
Message character string (Up to 16
characters)
Example
Set the message “test” to message No. 5.
SG05, test
Comments
• For details of the character strings that can be used
in messages, see the characters in the table of
ASCII codes on Page 5-11.
Message copy
Mode
Operation mode
Setting
SGp1, p2, p3
p1
COPY
p2
Message number at a message source (01 to
20)
p3
Message number at a message destination
(01 to 20)
Example
Copy message No. 5 to message No. 12.
SGCOPY, 05, 12
ST
Sets a tag.
Mode
Operation mode
Setting
STp1, p2
p1
Channel number (001 to 560)
Computation channel number (A01 to A60)
p2
Tag character string (up to 16 characters)
Example
Set “TEST” as the tag for channel 6 in slot 3 of
subunit 4.
ST436, TEST
Comments
• For details of the character strings that can be used
as tags, see the characters in the table of ASCII
codes on Page 5-11.
• The optional computation channel number for a
stand-alone model is A01 to A30.
SH
Sets a header.
Mode
Operation mode
Setting
SHp1, p2
p1
Setting line number (1 to 5)
p2
Header character string
Example
Set the line of number 2 to “TEST RECORDE.”
SH2, TEST RECORDE
Comments
• Set the character string to be printed in the first
place of a record.
• For details of the character strings that can be used
as headers, see the characters in the table of ASCII
codes on Page 5-11.
• Parameter p2 can have no more than 60 characters
for theDR130 and no more than 80 characters for
the DR230/240.
SJ
Sets a title.
Mode
Operation mode
Setting
SJp1
p1
Title character string (up to 32 characters)
Example
Set the title to “TEST RECORDE.”
SJTEST RECORDE
Comments
• Sets a character string which is recorded in a fixed
interval in analog recording. The interval to be
recorded is set using the XR command (see 6-9).
• For details of character strings that can be used as
titles, see the characters in the table of ASCII
codes on Page 5-11.
SF
Sets the format for list printing.
Mode
Operation mode
Setting
SFp1, p2, p3, p4
p1
ON/OFF of range list printing (ON, OFF)
p2
ON/OFF of alarm list printing (ON, OFF)
p3
ON/OFF of parameter list related to printing
(ON, OFF)
p4
ON/OFF of other parameters (ON, OFF)
6.4 Setting the Recording