Yokogawa DR240 User Manual
Page 56

6-2
IM DR231-11E
• Set the span values, p6 and p7, within the
measurement range indicated on page 5-8.
• Input values within 6 digits disregarding the
decimal point for p6 and p7. The decimal point
position is fixed to the decimal point position of
the setting range of page 5-8.
• The measurement range cannot be changed while
executing a report.
• The measurement range cannot be changed while
executing a report or computation, or when a file
is written.
Setting the strain input(DR232/DR242)
Setting
SRp1, p2, p3, p4, p5
p1
Channel number (001 to 560)
p2
STRAIN
p3
Measurement range
2k/20k/200k
p4
Left value of span
p5
Right value of span
Example
Set the measurement range of subunit 1 and channel
01 to 20k, left value of span to 0, and right value of
span to 100.
SR101, STRAIN, 20k, 0, 100
Comments
• Even when the settings of p3 are the same
parameters, the measurement range of the strain
varies depending on the gauge method. For
details, refer to page 5-9.
• Set spans, p4 and p5, within the measurement
range indicated in page 5-9.
• Input values within 6 digits disregarding the
decimal point for p4 and p5.
• The measurement range cannot be changed while
executing a report or compuration, or when a file
is written.
Setting the pulse input(DR232/DR242)
Setting
SRp1, p2, p3, p4, p5, p6, p7, p8, p9
p1
Channel number (001 to 560)
p2
PULSE
p3
Measuring mode
RATE momentary pulse count mode
GATE contact ON/OFF detection mode
p4
Left value of span (0 to 30000)
p5
Right value of span (0 to 30000)
p6
Left value of scale (0 to 30000)
p7
Right value of scale (0 to 30000)
p8
Decimal point position of scale (0 to 4)
p9
Filter (ON or OFF)
Example
Set subunit 1 and channel 01 to momentary pulse
count mode, left value of span to 0, and right value
of span to 1000.
SR101, PULSE, RATE, 0, 1000, 0, 1000, 0
Comments
• When omitting p6, p7, or p8, omit all three.
• When summing the count number or the ON time,
set the computational expression with the SO
command, then execute computation start with the
EX command. When the pulse input module is
installed, the use of computation channels become
available without the math option. However, the
only computational expression available in this
case is TLOG.PSUM(XXX) for summing the
count number or the ON time.
• The measurement range cannot be changed while
executing a report or computation, or when a file
is written.
Setting Scaling
Setting
SRp1, p2, p3, p4, p5, p6, p7, p8, p9
p1
Channel number (001 to 560)
Conputation channel number (A01 to A60)
p2
SCL
p3
Type of input
VOLT DC voltage
TC
Thermocouple
RTD
Resistance temperature detector
DI
Contact
mA
DC current
p4
Measurement range
p5
Left value of span
p6
Right value of span
p7
Left value of scale (-30000 to 30000)
p8
Right value of scale (-30000 to 30000)
p9
Decimal point position of scale (0 to 4)
Example
Change channel 02 of subunit 0 to an input in which
1 V is converted to 0.00 and 5 V to 100.00.
SR002, SCL, VOLT, 6V, 1000, 5000, 0, 10000, 2
Comments
• For the p4 measurement range, see the range
parameter table on Pages 5-7 and 5-8.
• For the p5 and p6 setting spans, set them in the
ranges shown in the setting range on Pages 5-7
and 5-8.
• For p5 and p6 setting values, enter them within 6
digits excluding the decimal point.
• Select either to set all three parameters, p7, p8 and
p9, or to omit them all.
• The measurement range cannot be changed while
executing a report or computation, or when a file
is written.
Setting the power monitor scaling
Setting SRp1, p2, p3, p4, p5, p6, p7, p8, p9, p10, p11
p1
Channel number (001 to 560)
p2
SCL
p3
AC
p4
Wiring method
1Ph2W:
Single-phase two-wire system
1Ph3W:
Single-phase three-wire system
(only on a three-wire system)
3Ph3W-2I: Three-phase three-wire system
(only on a two-voltage two-
current three-wire system)
3Ph3W-3I: Three-phase three-wire system
(only on a three-voltage three-
current three-wire system)
3Ph4W:
three-phase four-wire system
(only on a three-wire system)
p5
Input range
25 V - 0.5 A
25 V - 5 A
250 V - 0.5 A
250 V - 5 A
p6
Measurement item
p7
Left value of span
p8
Right value of span
p9
Left value of scale (-30000 to 30000)
p10
Right value of scale (-30000 to 30000)
p11
Decimal point position of scale (0 to 4)
Example
Measure the active power on subunit 0 and channel
01, and convert 10W to 0.00 and 100W to 100.00.
SR001, SCL, AC, 3Ph3W-2I, 250V-0.5A, P1, 10,
100, 000, 10000, 2
Comments
• Settings of p4 and p5 are common within one
power monitor module. If the setting is changed,
the settings on other channels also change.
6.1 Setting the Input