2 specifications – Yokogawa DR240 User Manual
Page 13

2-3
IM DR231-11E
Overview and Specifications of RS-232-C Interface
2
2.2
Specifications
Electrical & mechanical specs
: Conform to the EIA RS-232-C Standard.
Connection format
: Point-to point
Communication format
: Half duplex
Synchronizing format
: Start-stop asynchronous transmission
(synchronized by start/stop bit)
Baud rate (bps)
: 150, 300, 600, 1200, 2400, 4800, 9600, 19200, 38400
START bit
: 1 bit, fixed.
Data length
: Either 7 or 8 bits (selectable).
Parity
: Even, Odd, or None (selectable).
STOP bit
: Either 1 or 2 bits (selectable).
Connector
: DBSP-JB25S (JAE)
Hardware handshake
: Transmission/reception control by DTR, RTS, CTS.
Software handshake
: Transmission control by XON, XOFF.
Reception buffer length
: 200 bytes
Escape sequence
: Trigger;
Status call.